ML4828
ELECTRICAL CHARACTERISTICS (Continued)
PARAMETER
CONDITIONS
MIN
PHASE MODULATOR
EAO Zero Duty Cycle Threshold
VRT = 0V
0
RAMP Delay to Output
RAMP Discharge Current
48
SOFT-START
Charge Current
VSS = 4V
Discharge Current
VSS = 1V
6
CURRENT LIMIT/SHUTDOWN
Current Limit Threshold
0.9
Pin 20 Delay to Output
(Note 1)
Pin 12 Shutdown Threshold
1.0
Pin 12 Restart Threshold
2.2
Pin 12 Charging Current
SDN Shutdown Threshold
–350
1.05
OUTPUT
Output Low Level
IOUT = 20 mA
IOUT = 100 mA
Output High Level
IOUT = –20 mA
4.9
IOUT = –100 mA
4.6
Rise/Fall Time
CL = 1000pF, (Note 1)
ZVS Programmable Delay
240
Delay Mismatch
RA/RB Reference Voltage
2.45
UNDER VOLTAGE LOCKOUT
Start Threshold
5.1
Stop Threshold
4.1
SUPPLY
Start Up Current
VCC < 6V
Shutdown Current
ICC
VCC = 5V, CL = 1000pF, TA = 25°C
Note 1: Limits are guaranteed by 100% testing, sampling, or correlation with worst-case test conditions.
Note 2: VCC must be brought above the UVLO start voltage (6V) before dropping to VCC = 5V to ensure start-up.
TYP.
0.5
50
–25
10
1.0
50
1.1
2.4
–460
1.6
0.01
0.1
4.95
4.7
5
280
0
2.5
5.85
4.2
0.6
100
5
MAX
UNITS
0.9
V
80
ns
95
mA
–50
µA
13.2
mA
1.1
V
ns
1.5
V
2.6
V
–550
µA
2.05
V
0.1
V
0.3
V
V
V
7
ns
315
ns
ns
2.55
V
6.6
V
4.3
V
1
mA
500
µA
7
mA
4