EM85000
APPLE DESKTOP BUS MOUSE CONTROLLER
LISTEN R3 COMMAND
CODE
DESCRIPTION
Listen SRQ Device
ID
R3 (B13) Address
Number
- - - - B15 ~ B8 B7~B0
3B - - - - - - - - FF
Self Test.
3B - - - - A3 A2 A1 A0 FE
Device will change to new address(A0~A3)if no collision
has been detected.
3B - - - - A3 A2 A1 A0 FD
Device will change to new address(A0~A3)if no collision
and /Mkey is pressed.
3B 0 1 - 1 A3 A2 A1 A0 00
IF no collision has been detected,device will change to
new address (A0~A3)and set (or clear)SRQ depend on B13(R3).
3B - - - - - - - - 01
2 counts/dot for X/Y axis.
3B - - - - - - - - 02
1 count/dot for X/Y axis.
1. LISTEN R3:Host transmits data to device.
2. IF mouse Address=3 and Command=Listen R3 then command data=3B.(Ref table 1)
3. B0 ~ B 15:R3 control register.
TABLE 4
REGISTER DESCRIPTION
REGISTER 0 (R0):mouse counter data.
B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0
M Y6 Y5 Y4 Y3 Y2 Y1 Y0 R X6 X5 X4 X3 X2 X1 X0
1. X0 ~ X6:X direction counter data.
2. Y0 ~ Y6:Y direction counter data.
3. X6(Y6)=0:Positive count when mouse move to right(down).
X6(Y6)=1:Negative count when mouse move to left(up).
Negative count uses 2’S complement form.
4. R:When right key is pressed,B7 is cleared to zero,otherwise B7 status is set to one.
5. M:When main key is pressed,B15 is cleared to zero,otherwise B15 status is set to one.
REGISTER 3 (R3):control register.
B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0
0 EE SRQ 1 A3 A2 A1 A0 D7 D6 D5 D4 D3 D2 D1 D0
1. D0 ~ D7:Device Handler ID number. (00h ~ FFh)
2. A0 ~ A3:Device Address can be changed when host send LISTEN R3 command with ID=00,FE,FD.
3. B12:Always be“1”.
4. SRQ:Can be set or cleared when host send LISTEN R3 command with ID=00.
SRQ=1:Device can transmit data to Host.
SRQ=0:Device can’t transmit data to Host.
5. EE(Exception Event status):No use=1.
6. B15:Always be“0”.
SIGNAL PROTOCOL
1. Attn(800us)+Sync(65us):Synchronous signal.
Host out Attn+Sync signals to tell device when to get command code.
2. Data and command code:Data bit is discriminated by pulse code modulation.
* This specification are subject to be changed without notice.