DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

SA9607MSA Ver la hoja de datos (PDF) - South African Micro Electronic Systems

Número de pieza
componentes Descripción
Fabricante
SA9607MSA
Sames
South African Micro Electronic Systems Sames
SA9607MSA Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
SA9607M
TYPICAL APPLICATION
In Figure 1, the components required for a stand-alone power
metering application, is shown.
Current transformers are used for mains current sensing. The
channel showing the highest power consumption will be
selected by the SA9607M for energy metering.
The most important external components for the SA9607M
integrated circuit are the current sense resistors, the voltage
sense resistors as well as the bias setting resistor.
Current Sense Resistors
The resistors R1, R2, R3 and R4 define the current level into
the current sense inputs of the device. The component should
be selected for input currents of 16µARMS into the current
channels of the SA9607M at IMAX (rated current of the meter).
The voltage drop of the resistors R10 and R17 should be at least
20mV.
Current Channel 1
R1= R2= (IL/16µARMS) x R10/2
Current Channel 2
R3= R4= (IL/16µARMS) x R11/2
Where:
IL = Line current/CT-ratio
R10 = Termination resistor
R11 = Termination resistor
Voltage Sense Resistors
R9, R8, R6 and R5 set the current for the voltage sense input.
The values should be selected so that the input current into the
voltage sense input (virtual ground) is set to 14µARMS.
Bias Resistor
R7 defines all on-chip bias and reference currents. With R7 =
24k, optimum conditions are set.
R7 may be varied within ±10% for calibration purposes. Any
change to R7 will affect the output quadratically (i.e.: R7 = +5%,
fP = +10%).
http://www.sames.co.za.
7/10