Philips Semiconductors
LCD controllers/drivers
Product specification
PCF2119X
7.17 Reset function
The PCF2119x must be reset externally when power is turned on. The reset executes a ‘clear display’, requiring
165 oscillator cycles. After the reset the chip has the state shown in Table 4.
Table 4 State after reset
STEP
1
2
3
4
5
6
7
8
9
10
11
FUNCTION
CONTROL BIT STATE
CONDITION
clear display
entry mode set
I/D = 1
+1 (increment)
S=0
no shift
display control
D=0
display off
C=0
cursor off
B=0
cursor character blink off
function set
DL = 1
8-bit interface
M=0
1-line display
H=0
normal instruction set
SL = 0
MUX 1 : 18 mode
default address pointer to DDRAM; the Busy Flag (BF) indicates the busy state (BF = 1) until
initialization ends; the busy state lasts 2 ms; the chip may also be initialized by software; see
Tables 18 and 19
icon control
IM, IB = 00
icons/icon blink disabled
display/screen configuration
L = 0; P = 0; Q = 0
default configurations
VLCD temperature coefficient
set VLCD
I2C-bus interface reset
TC1 = 0; TC2 = 0
default temperature coefficient
VA = 0; VB = 0 (VLCD generator off)
set HVgen stages
S1 = 1, S0 = 0
HVgen set to 3 internal stages
(4 voltage multipliers)
2003 Jan 30