DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

PBL38640-2 Ver la hoja de datos (PDF) - Ericsson

Número de pieza
componentes Descripción
Fabricante
PBL38640-2 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
PBL 386 40/2
15
16
}C3
C2
C1, C2 and C3 are digital inputs (internal pull-up) controlling the SLIC operating states.
Refer to section "Operating states" for details.
17
C1
18
DET
Detector output. Active low when indicating loop detection and ring trip, active high when indicating
ground key detection.
19
NC
No internal Connection
20
VCC
+5 V power supply.
21
PLD
Programmable Loop Detector threshold. The loop detection threshold is programmed by a resistor
connected from this pin to AGND.
22
POV
Programmable Overhead Voltage. If pin is left open: The overhead voltage is internally set to min 2.7 V in
off-hook and min 1.1 V in On-hook. If a resistor is connected between this pin and AGND: the overhead
voltage can be set to higher values.
23
PLC
Prog. Line Current, the current limit, reference C in figure 13, is programmed by a resistor connected
from this pin to AGND.
24
REF
A Reference, 49.9 k, resistor should be connected from this pin to AGND.
25
NC
No internal Connection
26
RSN
Receive Summing Node. 200 times the AC-current flowing into this pin equals the metallic (transversal)
AC-current flowing from RINGX to TIPX. Programming networks for two-wire impedance and receive
gain connect to the receive summing node. A resistor should be connected from this pin to AGND.
27
AGND Analog Ground, should be tied together with BGND.
28
VTX
Transmit vf output. The AC voltage difference between TIPX and RINGX, the AC metallic voltage, is
reproduced as an unbalanced GND referenced signal at VTX with a gain of one (or one half, see pin
PTG). The two-wire impedance programming network connects between VTX and RSN.
SLIC Operating States
State C3
C2
C1
SLIC operating state
Active detector
0
0
0
0
Open circuit
1
0
0
1
Ringing state
2
0
1
0
Active state
3
0
1
1
Active state
4
1
0
0
Tip open state
5
1
0
1
Active state
6
1
1
0
Active reverse
7
1
1
1
Active reverse
-
Ring trip detector (active low)
Loop detector (active low)
Line voltage measurement (note 9)
Loop detector (active low)
Ground key detector (active high)
Loop detector (active low)
Ground key detector (active high)
Table 1. SLIC operating states.
9

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]