PBL 3766
Absolute Maximum Ratings
Parameter
Temperature and humidity
Storage temperature range
Operating temperature range
Operating junction temperature
Storage humidity
Power supply, -10 °C < TAmb < 80 °C
VCC with respect to GND
VEE with respect to GND
VBat with respect to GND
Power dissipation
Continuous
power
dissipation
at
T
Amb
70
°C
Peak power dissipation at TAmb = 70°C, t < 10 ms, trep > 10 sec.
Relay driver
Ring relay supply voltage
Ring relay current
Ring trip comparator
Input voltage
Input current
Digital inputs, outputs (C1, C2, E0, DET)
Input voltage
Output voltage (DET disabled)
Output current (DET enabled)
TIPX or RINGX terminals, VBAT = -50 V
TIPX or RINGX voltage, continuous, (Note 1)
TIPX or RINGX pulse = tω < 10 ms, trep > 10 s (Notes 2, 3)
TIPX or RINGX pulse = tω < 1 µs, trep > 10 s (Notes 2, 3)
TIP or RING pulse = tω < 250 ns, trep > 10 s (Notes 2, 3)
TIPX or RINGX current
Active
Stand-by
Recommended Operating Conditions
Parameter
Case temperature
VCC with respect to ground
VEE with respect to ground
VBat with respect to ground (Note 4)
Symbol
Min
Max
Unit
TStg
-60
TCase
-10
TJ
-10
RH
5
+150
+110
+140
95
°C
°C
°C
% RH
VCC
-0.5
6.5
V
VEE
-6.5
0.5
V
VBat
-70
VEE+0,7 V
P
1.5
W
D
PDP
4
W
VRRly
VBat
0
V
IRRly
50
mA
VDT
VBat
0
V
IDT
-2
2
mA
VID
0
VOD
0
IOD
VCC
V
VCC
V
5
mA
VT, VR
VBat
0.5
V
VT, VR
VBat - 20 5
V
VT, VR
VBat - 40 10
V
VT, VR
VBat - 70 15
V
ILdc + ILodc
ILdc
80
mA
25
mA
Symbol
Min
Max
Unit
TCase
VCC
VEE
VBat
0
90
°C
4.75
5.25
V
-5.25
-4.75
V
-58
-24
V
Notes
1. With a diode (D2) connected in series with the VBat supply, as shown in figure 11, -70 V may be continuously applied to the
TIPX or RINGX lead.
2. These voltage ratings require a diode (D2) to be installed in series with the VBat supply as shown in figure 11.
3. VT and VR are referenced to ground. tω is the pulse width of a rectangular test pulse and trep is the pulse repetition rate.
4. -24 V < V < -21 V may be used in applications requiring maximum vf signal amplitudes less than 3 V (8.75 dBm, 600 ohms).
Bat
pk
4-2