GS70/100T300 Family
ADJUSTMENT OF THE OUTPUT VOLTAGE
The output voltage can be fixed following the indi-
cations given in fig. 2. The external reference volt-
age Vadj can be calculated using the following
formula:
Vadj = 5 • Vo
Vnom
The Vout and Vadj ranges are given in the following
table:
Table 1: Output voltage generation with external voltage generator
Type
GS70T300-3.5
GS100T300-5
GS100T300-12
GS100T300-15
GS100T300-24
GS100T300-48
Nominal Output
Voltage (V)
3.5
5.2
12.0
15.0
24.0
48.0
Output Voltage
Range (Vout)
1.75 to 3.50
2.60 to 5.20
6.00 to 13.20
7.50 to 16.50
12.00 to 26.40
24.00 to 52.80
Figure 2. Output voltage adjustment
External Voltage
Generator allowed
Range (Vadj)
2.5 to 5.0
2.5 to 5.0
2.5 to 5.5
2.5 to 5.5
2.5 to 5.5
2.5 to 5.5
9/10