DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

NJM3545 Ver la hoja de datos (PDF) - Japan Radio Corporation

Número de pieza
componentes Descripción
Fabricante
NJM3545
JRC
Japan Radio Corporation  JRC
NJM3545 Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
NJM3545
s FUNCTIONAL DESCRIPTION
The circuit NJM3545 is a low side driver capable of driving resistive or inductive loads not exceeding 2 A.
The driver has an error indicating function which generates an Error output signal when a fault condition has
occurred.
The circuits NJM3545 and NJM3548 are complementary drivers with equivalent functions and similar data.
NJM3545 is a sink driver and NJM3548 is a source driver.
Input stage
The output stage is switched on and off according to the status of the input. HIGH level activates the output. If the
input is left open, the circuit will accept it as a LOW level.
Output stage
The output stage contains a power transistor and two clamping diodes. The diodes are used for terminating line
transients from inductive loads. If the driver is inactive and the output is shorted to GND the driver will leak maxi-
mum
8 µA. See figure 18.
Protection circuit
The circuit contains two protection circuits:
• Overload and Short circuit protection
• Thermal protection
The
overload
and
short
circuit
protection
will
be
activated
at
I=
out
3.5
A
typically
at
T=
J
+25°C,
see
figure
20.
The output will be turned off immediately and latched to a high-impedance state after an overload or short circuit
has been detected.
I Ref
5
Input
1
CC
2
Output
GND
3
Figure 5. Input stage
3
Figure 6. Output stage
GND
Fault condition
Input
Normal
0 LOW
1 HIGH
VOUT Short to GND 0 LOW
1 HIGH
VOUT Short to VCC
0 LOW
1 HIGH
Open load
0 LOW
1 HIGH
Over temperature 0 LOW
TJ=130 °C
1 HIGH
Figure 7. Error table
Output
1 OFF
0 ON
1 OFF
0 ON
1 OFF
1 OFF
1 OFF
0 ON
1 OFF
1 OFF
Error
LOW=Error
HIGH=Normal
How to resume normal operation
1 HIGH
1 HIGH
0 LOW
0 LOW
1 HIGH
0 LOW
1 HIGH
0 LOW
1 HIGH
0 LOW
——
——
Remove fault condition.
Remove fault condition.
——
Turn off and on after fault condition is removed.
——
Attach proper load to output or turn off the driver.
——
Temperature is reduced to approx 120°C, or turn off the driver.