MX29LV081B
TABLE 4. MX29LV081B COMMAND DEFINITIONS
Command
First Bus
Bus Cycle
Second Bus Third Bus
Cycle
Cycle
Fourth Bus
Cycle
Cycle Addr Data Addr Data Addr Data Addr Data
Fifth Bus
Cycle
Sixth Bus
Cycle
Addr Data Addr Data
Reset
1 XXXH F0H
Read
1 RA RD
Read Manufacturer ID 4 XXXH AAH XXXH 55H XXXH 90H X00H C2H
Read Silicon ID
4 XXXH AAH XXXH 55H XXXH 90H ADI DDI
Sector Protect
4 XXXH AAH XXXH 55H XXXH 90H (SA) 00H
Verify
x02H 01H
Program
4 XXXH AAH XXXH 55H XXXH A0H PA PD
Chip Erase
6 XXXH AAH XXXH 55H XXXH 80H XXXH AAH XXXH 55H XXXH 10H
Sector Erase
6 AAAH AAH 555H 55H AAAH 80H AAAH AAH 555H 55H SA 30H
Sector Erase Suspend 1 XXXH B0H
Sector Erase Resume 1 XXXH 30H
Note:
1. ADI = Address of Device identifier; A1=0, A0 = 0 for manufacturer code,A1=0, A0 = 1 for device code. A2-A19=do not care.
(Refer to table 2)
DDI = Data of Device identifier : C2H for manufacture code, 38H for device code.
X = X can be VIL or VIH
RA=Address of memory location to be read.
RD=Data to be read at location RA.
2.PA = Address of memory location to be programmed.
PD = Data to be programmed at location PA.
SA = Address of the sector to be erased.
3. For Sector Protect Verify operation: If read out data is 01H, it means the sector has been protected. If read out data is 00H,
it means the sector is still not being protected.
P/N:PM1115