DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

33999 Ver la hoja de datos (PDF) - Motorola => Freescale

Número de pieza
componentes Descripción
Fabricante
33999
Motorola
Motorola => Freescale Motorola
33999 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Freescale Semiconductor, Inc.
STATIC ELECTRICAL CHARACTERISTICS
Characteristics noted under conditions of 3.1 V SOPWR 5.5 V, 5.0 V VPWR 18 V, -40°C TC 125°C, unless otherwise
noted. Where applicable, typical values reflect the parameter’s approximate average value with VPWR = 13 V, TA = 25°C.
Characteristic
Symbol
Min
Typ
Max
Unit
POWER INPUT
Supply Voltage Range
Fully Operational
VPWR(FO)
V
5.0
27
Supply Current
All Outputs ON, IOUT = 0.3 A
IPWR(ON)
mA
4.0
8.0
Sleep State Supply Current at RST 0.2 SOPWR and/or SOPWR
IPWR(SS)
-10
1.0
10
µA
0.5 V
Overvoltage Shutdown
VOV
27.5
31.5
35
V
Overvoltage Shutdown Hysteresis
VOV (HYS)
0.8
1.4
2.3
V
VPWR Undervoltage Shutdown
VPWR(UV)
3.2
3.5
V
SPI Interface Logic Supply Voltage
SPI Interface Logic Supply Current (RST Pin High)
SPI Interface Logic Supply Current (RST Pin Low)
SOPWR
3.1
5.5
V
ISOPWR(RSTH)
100
500
µA
ISOPWR(RSTL)
-10
10
µA
SPI Interface Logic Supply Undervoltage Lockout Threshold
SOPWR (UNVOL)
2.0
2.5
3.0
V
POWER OUTPUT
Drain-to-Source ON Resistance (IOUT = 0.35 A, VPWR = 13 V)
RDS(ON)
TJ = 125°C
TJ = 25°C
TJ = -40°C
0.75
1.2
0.55
1.2
0.45
1.2
Output Self-Limiting Current
Outputs Programmed ON
IOUT (lim)
A
0.9
1.2
2.5
Output Fault Detect Threshold (Note 11)
Outputs Programmed OFF
VOUTth(F)
V
2.5
3.0
3.5
Output OFF Open Load Detect Current (Note 12)
Outputs Programmed OFF (VPWR = 5.0 V)
Outputs Programmed OFF (VPWR = 13 V, 18 V)
I OCO(5)
25
IOCO(13,18)
30
µA
50
100
50
100
Output Clamp Voltage
2.0 mA IOUT 200 mA
Output Leakage Current
SOPWR 2.0 V
VCL
V
45
50
55
IOUT (lkg)
µA
-10
2.0
10
Overtemperature Shutdown (Outputs OFF) (Note 13)
TLIM
155
165
180
°C
Overtemperature Shutdown Hysteresis (Note 13)
TLIM (hys)
5.0
10
20
°C
Notes
11. Output Fault Detect Thresholds with outputs programmed OFF. Output Fault Detect Thresholds are the same for output open and shorts.
12. Output OFF Open Load Detect Current is the current required to flow through the load for the purpose of detecting the existence of an open
load condition when the specific output is commanded to be OFF.
13. This parameter is guaranteed by design but is not production tested.
MOTOROLA ANALOG INTEGRATED CIRFCoUrITMDoErVeICEInDfAoTrAmation On This Product,
Go to: www.freescale.com
33999
5

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]