DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MC100EL90 Ver la hoja de datos (PDF) - ON Semiconductor

Número de pieza
componentes Descripción
Fabricante
MC100EL90 Datasheet PDF : 5 Pages
1 2 3 4 5
MC100EL90
VCC Q0 Q0 GND Q1 Q1 GND Q2 Q2 VCC
20 19 18 17 16 15 14 13 12 11
PECL
PECL
PECL
ECL
ECL
ECL
1 2 3 4 5 6 7 8 9 10
VCC D0 D0
D1 D1
D2 D2 VEE
Table 1. PIN DESCRIPTION
PIN
FUNCTION
Dn, Dn
Qn, Qn
ECL VBB
VCC
VEE
GND
ECL Inputs
PECL Outputs
ECL Reference Voltage Output
Positive Supply
Negative Supply
Ground
* All VCC pins are tied together on the die.
Warning: All VCC, VEE, and GND pins must be externally
connected to Power Supply to guarantee proper operation.
Figure 1. 20Lead Pinout and Logic Diagram (Top View)
Table 2. MAXIMUM RATINGS
Symbol
Parameter
Condition 1
Condition 2
Rating
Unit
VCC
PECL Mode Power Supply
VEE
NECL Mode Power Supply
VI
PECL Mode Input Voltage
NECL Mode Input Voltage
Iout
Output Current
VEE = 0 V
VCC = 0 V
VEE = 0 V
VCC = 0 V
Continuous
Surge
VI  VCC
VI  VEE
8 to 0
V
8 to 0
V
6 to 0
V
6 to 0
V
50
mA
100
mA
IBB
VBB Sink/Source
TA
Operating Temperature Range
Tstg
Storage Temperature Range
qJA
Thermal Resistance (JunctiontoAmbient) 0 lfpm
500 lfpm
SOIC20
SOIC20
± 0.5
40 to +85
65 to +150
90
60
mA
°C
°C
°C/W
°C/W
qJC
Thermal Resistance (JunctiontoCase) Standard Board
SOIC20
30 to 35
°C/W
Tsol
Wave Solder
Pb
PbFree
265
°C
265
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
Table 3. PECL DC CHARACTERISTICS VCC = 5.0 V; VEE = 5 V; GND = 0 V (Note 1)
40°C
25°C
85°C
Symbol
Characteristic
Min Typ Max Min Typ Max Min Typ Max Unit
ICC
VCC Power Supply Current
24
20
24
26 mA
VOH
Output HIGH Voltage (Note 2)
3915 3995 4120 3975 4045 4120 3975 4050 4120 mV
VOL
Output LOW Voltage (Note 2)
3170 3305 3445 3190 3295 3380 3190 3295 3380 mV
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. Output parameters vary 1:1 with VCC. VCC can vary ± 0.5 V.
2. Outputs are terminated through a 50 W resistor to VCC 2.0V.
http://onsemi.com