MBM29LV001TC-55/-70/MBM29LV001BC-55/-70
Table 6 MBM29LV001TC/001BC Standard Command Definitions
Command
Sequence
Bus
Write
Cycles
First Bus Second Bus Third Bus
Write Cycle Write Cycle Write Cycle
Fourth Bus
Read/Write
Cycle
Fifth Bus
Write Cycle
Sixth Bus
Write Cycle
Req’d Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data
Read/Reset *1
1 XXXH F0H — — — — — — — — — —
Read/Reset *1 3 555H AAH 2AAH 55H 555H F0H RA RD — — — —
Autoselect
3 555H AAH 2AAH 55H 555H 90H — — — — — —
Program
4 555H AAH 2AAH 55H 555H A0H PA PD — — — —
Chip Erase
6 555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H 555H 10H
Sector Erase
6 555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H SA 30H
Set to
Fast Mode
3 555H AAH 2AAH 55H 555H 20H — — — — — —
Fast Program *2 2 XXXH A0H PA PD — — — — — — — —
Reset from Fast
Mode
*2
2
XXXH 90H XXXH F0H —
Extended *3
Sector Protect
4 XXXH 60H SPA 60H SPA 40H SPA SD — — — —
Sector Erase Suspend Erase can be suspended during sector erase with Addr. (“H” or “L”). Data (B0H)
Sector Erase Resume Erase can be resumed after suspend with Addr. (“H” or “L”). Data (30H)
Notes:
1. Address bits A11 to A16 = X = “H” or “L” for all address commands except or Program Address (PA) and
Sector Address (SA)
2. Bus operations are defined in Table 2.
3. RA =Address of the memory location to be read
PA = Address of the memory location to be programmed
Addresses are latched on the falling edge of the write pulse.
SA =Address of the sector to be erased. The combination of A16, A15, A14, A13 and A12 will
uniquely select any sector.
4. RD =Data read from location RA during read operation.
PD =Data to be programmed at location PA. Data is latched on the falling edge of write pulse.
5. SPA =Sector address to be protected. Set sector address (SA) and (A6, A1, A0) = (0, 1, 0).
SD =Sector protection verify data. Output 01H at protected sector addresses and output 00H at
unprotected sector addresses.
*1:Both Read/Reset commands are functionally equivalent, resetting the device to the read mode.
*2:This command is valid while Fast Mode.
*3:This command is valid while RESET=VID.