FUJITSU SEMICONDUCTOR
DATA SHEET
ASSP
AD/DA CONVERTER
DS04-28500-5E
MB40166/MB40176
1-CHANNEL 6-BIT AD/DA CONVERTER WITH CLAMP
CIRCUIT
The Fujitsu MB40166 and MB40176 are low power 6-bit AD/DA converter which
is fabricated with Fujitsu Advanced Bipolar Technology. MB40166 and MB40176
have the same basic circuits and functions, with the only difference being that
MB40166 has an independent analog input terminal for the A/D section and a
clamp voltage output terminal, while MB40176 has an analog input in the A/D
section internally connected with the clamp circuit.
Since both models contain a single-chip clamp circuit and a reference voltage
circuit, they are ideal for video signal processing.
• Resolution
:6 bits
• Linearity Error
:±0.8% max.
• Maximum Conversion Rate
:20 MSPS min.
• Analog Input Voltage Range :VREF to VCCA (MB40166)
0 to 1.0 V (MB40176)
• Analog Output Voltage Range :VCC to VCC -1 V
• Digital I/O Level
:TTL Level
• Power Supply Voltage
:+5 V
• Power Dissipation:300 mW typ.
• Package
28pin Plastic FLAT Package (Suffix : -PF)
28pin Plastic DIP Package (Suffix : -P)
ABSOLUTE MAXIMUM RATINGS (see NOTE)
Rating
Symbol
Value
Unit
Power Supply Voltage
VCCA, VCCD
-0.5 to +7.0
V
Digital Input Voltage
VIND
-0.5 to +7.0
V
Analog Input Voltage
VINA
-0.5 to VCCA +0.5
V
Storage Temperature
TSTG
-55 to +125
°C
NOTE:
Permanent device damage may occur if the above Absolute Maximum
Ratings are exceeded. Functional operation should be restricted to the
conditions as detailed in the operational sections of this data sheet.
Exposure to absolute maximum rating conditions for extended periods
may affect device reliability.
PLASTIC PACKAGE
FPT-28P-M01
PLASTIC PACKAGE
DIP-28P-M03
This device contains circuitry to protect the inputs against
damage due to high static voltages or electric fields. However,
it is advised that normal precautions be taken to avoid
application of any voltage higher than maximum rated voltages
to this high impedance circuit.