DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX4712C Ver la hoja de datos (PDF) - Maxim Integrated

Número de pieza
componentes Descripción
Fabricante
MAX4712C Datasheet PDF : 17 Pages
First Prev 11 12 13 14 15 16 17
Fault-Protected, Low-Voltage,
Quad SPST Analog Switches
V+
NO_
(NC_)
IN_
NORMALLY OPEN SWITCH CONSTRUCTION
HIGH
FAULT
N1
LOW
FAULT
ON
P2
P1
COM_
GND
N2
V-
-ESD DIODE
NC SWITCH
Figure 1. Block Diagram
NC_) and COM_ so that signals pass equally well in
either direction.
Positive Fault Condition
When the signal on NO_ (or NC_) exceeds V+ by about
150mV, the high-fault comparator output is high, turn-
ing off FETs N1 and P1. This makes the NO_ (or NC_)
input high impedance regardless of the switch state. If
the switch state is “off”, all FETs are turned off and both
NO_ (or NC_) and COM_ are high impedance. If the
switch state is “on”, clamp FET P2 is turned on, sourc-
ing current from V+ to COM_.
Negative Fault Condition
When the signal on NO_ (or NC_) exceeds V- by about
150mV, the low-fault comparator output is high, turning
off FETs N1 and P1. This makes the NO_ (or NC_) input
high impedance regardless of the switch state. If the
switch state is “off”, all FETs are turned off and both
NO_ (or NC_) and COM_ are high impedance. If the
switch state is “on”, clamp FET N2 is turned on, sinking
current from COM_ to V-.
Transient Fault Response and Recovery
When a fast rise-time or fall-time transient on NC_ or
NO_ exceeds V+ or V-, the output (COM_) follows the
input to the supply rail with only a few nanoseconds
delay. This delay is due to the switch on-resistance and
circuit capacitance to ground. When the input transient
returns to within the supply rails, however, there is a
700ns output recovery delay time. These values
depend on the COM_ output resistance and capaci-
tance, and are not production tested or guaranteed.
The delays are not dependent on the fault amplitude.
Higher COM_ output resistance and capacitance
increase recovery times.
COM_ and IN_ Pins
FETs N2 and P2 can source about ±15mA from V+ or
V- to COM_ in the fault condition. Ensure that if the
COM_ pin is connected to a low-resistance load, the
absolute maximum current rating of 40mA is never
exceeded both in normal and fault conditions.
______________________________________________________________________________________ 11

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]