DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX4172 Ver la hoja de datos (PDF) - Maxim Integrated

Número de pieza
componentes Descripción
Fabricante
MAX4172 Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
MAX4172
Low-Cost, Precision, High-Side
Current-Sense Amplifier
Table 1. Suggested Component Values
FULL-SCALE
LOAD CURRENT
(A)
0.1
1
5
10
CURRENT-SENSE
RESISTOR,
RSENSE (mΩ)
1000
100
20
10
OUTPUT
RESISTOR, ROUT
(kΩ)
3.48
3.48
3.48
3.48
FULL-SCALE
OUTPUT
VOLTAGE, VOUT (V)
3.48
3.48
3.48
3.48
SCALE FACTOR,
VOUT/ISENSE (V/A)
34.8
3.48
0.696
.348
Sense Resistor, RSENSE
Choose RSENSE based on the following criteria:
Voltage Loss: A high RSENSE value causes the
power-source voltage to degrade through IR loss. For
minimal voltage loss, use the lowest RSENSE value.
Accuracy: A high RSENSE value allows lower currents
to be measured more accurately. This is because
offsets become less significant when the sense
voltage is larger. For best performance, select RSENSE
to provide approximately 100mV of sense voltage for
the full-scale current in each application.
Efficiency and Power Dissipation: At high current
levels, the I2R losses in RSENSE can be significant.
Take this into consideration when choosing the resistor
value and its power dissipation (wattage) rating. Also,
the sense resistor’s value might drift if it is allowed to
heat up excessively.
Inductance: Keep inductance low if ISENSE has a
large high-frequency component. Wire-wound resis-
tors have the highest inductance, while metal film is
somewhat better. Low-inductance metal-film resistors
are also available. Instead of being spiral wrapped
around a core, as in metal-film or wirewound resistors,
they are a straight band of metal and are available in
values under 1Ω.
Cost: If the cost of RSENSE is an issue, you might
want to use an alternative solution, as shown in Figure
2. This solution uses the PCB traces to create a sense
resistor. Because of the inaccuracies of the copper
resistor, the full-scale current value must be adjusted with
a potentiometer. Also, copper’s resistance temperature
coefficient is fairly high (approximately 0.4%/°C).
In Figure 2, assume that the load current to be measured
is 10A, and that you have determined a 0.3-inchwide,
2-ounce copper to be appropriate. The resistivity of
0.1-inch-wide, 2-ounce (70μm thickness) copper is 30mΩ/
ft. For 10A, you might want RSENSE = 5mΩ for a 50mV
drop at full scale. This resistor requires about 2 inches of
0.1-inch-wide copper trace.
INPUT
O.3 in. COPPER
RSENSE
O.1 in. COPPER
LOAD/BATTERY
O.3 in. COPPER
VSENSE
1 RS+
V+ 8
2
MAX4172
RS-
OUT 6
GND 5
VSUPPLY
3V TO 32V
ROUT
Figure 2. MAX4172 Connections Showing Use of PC Board
Current-Sense Adjustment
(Resistor Range, Output Adjust)
Choose ROUT after selecting RSENSE. Choose ROUT
to obtain the full-scale voltage you require, given the
full-scale IOUT determined by RSENSE. OUT’s high
impedance permits using ROUT values up to 200kΩ with
minimal error. OUT’s load impedance (e.g., the input of an
op amp or ADC) must be much greater than ROUT (e.g.,
100 x ROUT) to avoid degrading measurement accuracy.
High-Current Measurement
The MAX4172 can achieve high-current measurements by
using low-value sense resistors, which can be paralleled
to further increase the current-sense limit. As an alternative,
PCB traces can be adjusted over a wide range.
www.maximintegrated.com
Maxim Integrated 7

Share Link: 