MASW-009482
GaAs Broadband High Power SP3T Switch
DC - 4.0 GHz
Rev. V1
Applications Section: Tri-Mode Mobile Phone Performance
Typical Electrical Performance: TA = 25°C, Z0 = 50Ω, VC = 0V/2.6V, 1000pF Capacitors 1
Parameter
Test Conditions
Units Min. Typ. Max.
Insertion Loss
(All Paths)
824 - 894 MHz (CELL)
1710 - 1755 MHz (AWS)
1850 - 1990 MHz (PCS)
dB
0.55
dB
0.65
dB
0.75
Isolation
824 - 894 MHz (CELL)
1710 - 1755 MHz (AWS)
1850 - 1990 MHz (PCS)
dB
27
dB
23
dB
22
Return Loss
(All RF ports)
DC - 2.5 GHz
dB
20
Input IP3
Two Tone, +23 dBm/tone, 1 MHz Spacing, 894 MHz
Two Tone, +23 dBm/tone, 1 MHz Spacing, 1755 MHz
Two Tone, +23 dBm/tone, 1 MHz Spacing, 1990 MHz
dBm
dBm
dBm
68
65
67
For Cell Band: Two-tone signal input:
TX1 = +22 dBm @ 820 MHz, TX2 = +22 dBm @ 821 MHz, dBm
-105
RX interferer = -23 dBm @ 865 MHz2
Cross Modulation
For PCS Band: Two-tone signal input:
TX1 = +18 dBm @ 1880 MHz, TX2 = +18 dBm @ 1881 MHz, dBm
-103
RX interferer = -23 dBm @ 1960 MHz2
2nd Harmonic
Fin = 894 MHz, Pin = +25.5 dBm
Fin = 1755 MHz, Pin = +25.0 dBm
Fin = 1990 MHz, Pin = +24.0 dBm
dBc
dBc
dBc
81
81
85
3rd Harmonic
Fin = 894 MHz, Pin = +25.5 dBm
Fin = 1755 MHz, Pin = +25.0 dBm
Fin = 1990 MHz, Pin = +24.0 dBm
dBc
dBc
dBc
82
81
91
Input P0.1dB
Fin = 894 MHz
Fin = 1755 MHz
Fin = 1990 MHz
dBm
34.5
dBm
36.0
dBm
35.5
Trise, Tfall
10% to 90% RF, 90% to 10% RF, 900 MHz
ns
45
Ton, Toff
50% control to 90% RF, and 50% control to 10% RF,
900 MHz
ns
70
Transients
In Band
mV
40
Control Current
VC = 0 V/2.6 V
µA
6
1. External DC blocking capacitors are required on all RF ports. Typical performance specifications are with 1000 pF blocking and decoupling
capacitors / as shown on the application schematic .
2. RX Interferer power set to 10 dBm during test to improve dynamic range of measurement system. Typical performance with 23 dBm
interferer is determined by using a linear relationship between interferer power level and cross modulation products.
6
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]