UU W U
APPLICATIO S I FOR ATIO
LTC485 Line Length vs Data Rate
The maximum line length allowable for the RS422/RS485
standard is 4000 feet.
LTC485
Figures 17 and 18 show that the LTC485 is able to
comfortably drive 4000 feet of wire at 110kHz.
A
LTC485
B
NOISE
TTL GENERATOR
IN
100
C
D
LTC485
TTL
OUT
4000 FT 26AWG
TWISTED PAIR
RO
COMMON-MODE
VOLTAGE (A + B)/2
DI
Figure 14. Line Length Test Circuit
Using the test circuit in Figure 14, Figures 15 and 16 show
that with ~ 20VP-P common-mode noise injected on the
line, The LTC485 is able to reconstruct the data stream at
the end of 4000 feet of twisted pair wire.
RO
LTC485 • F17
Figure 17. System Common-Mode Voltage at 110kHz
RO
COMMON-MODE
VOLTAGE (A – B)
DI
COMMON-MODE
VOLTAGE (A + B)/2
DI
LTC485 • F15
Figure 15. System Common-Mode Voltage at 19.2kHz
LTC485 • F18
Figure 18. System Differential Voltage at 110kHz
When specifying line length vs maximum data rate the
curve in Figure 19 should be used:
10k
RO
DIFFERENTIAL
VOLTAGE A – B
DI
LTC485 • F16
Figure 16. System Differential Voltage at 19.2kHz
1k
100
10
10k
100k
1M 2.5M 10M
MAXIMUM DATA RATE
LTC485 • F19
Figure 19. Cable Length vs Maximum Data Rate
9