Pin connection
L6228Q
Table 4.
Pin description
Pin
Type
Function
1, 21
GND
GND Ground terminals.
9
OUT1B Power Output Bridge B Output 1.
11
RCB
RC Pin
RC Network Pin. A parallel RC network connected between this pin and
ground sets the Current Controller OFF-Time of the Bridge B.
12
SENSEB
Power
Supply
Bridge B Source Pin. This pin must be connected to Power Ground through a
sensing power resistor.
13
VREFB
Analog Input
Bridge B Current Controller Reference Voltage.
Do not leave this pin open or connected to GND.
Step Mode Selector. HIGH logic level sets HALF STEP Mode, LOW logic
14 HALF/FULL Logic Input level sets FULL STEP Mode.
If not used, it has to be connected to GND or +5 V.
Decay Mode Selector. HIGH logic level sets SLOW DECAY Mode. LOW logic
15 CONTROL Logic Input level sets FAST DECAY Mode.
If not used, it has to be connected to GND or +5 V.
Chip Enable. LOW logic level switches OFF all Power MOSFETs of both
16
EN
Logic Input Bridge A and Bridge B. This pin is also connected to the collector of the
(1)
Overcurrent and Thermal Protection to implement over current protection.
If not used, it has to be connected to +5 V through a resistor.
17
VBOOT
Supply
Voltage
Bootstrap Voltage needed for driving the upper Power MOSFETs of both
Bridge A and Bridge B.
19
OUT2B Power Output Bridge B Output 2.
20
VSB
Power
Supply
Bridge B Power Supply Voltage. It must be connected to the Supply Voltage
together with pin VSA
22
VSA
Power
Supply
Bridge A Power Supply Voltage. It must be connected to the Supply Voltage
together with pin VSB
23
OUT2A Power Output Bridge A Output 2.
24
VCP
Output Charge Pump Oscillator Output.
Reset Pin. LOW logic level restores the Home State (State 1) on the Phase
25
RESET Logic Input Sequence Generator State Machine.
If not used, it has to be connected to +5 V.
26
VREFA
Analog Input
Bridge A Current Controller Reference Voltage.
Do not leave this pin open or connected to GND.
27
CLOCK Logic Input Step Clock input. The state machine makes one step on each rising edge.
Selects the direction of the rotation. HIGH logic level sets clockwise direction,
28 CW/CCW Logic Input whereas LOW logic level sets counterclockwise direction.
If not used, it has to be connected to GND or +5 V.
29
SENSEA
Power
Supply
Bridge A Source Pin. This pin must be connected to Power Ground through a
sensing power resistor.
30
RCA
RC Pin
RC Network Pin. A parallel RC network connected between this pin and
ground sets the Current Controller OFF-Time of the Bridge A.
31
OUT1A Power Output Bridge A Output 1.
1. Also connected at the output drain of the Over current and Thermal protection MOSFET. Therefore, it has to be driven
putting in series a resistor with a value in the range of 2.2 k- 180 k, recommended 100k