Parameter and Conditions, each channel
at Tj = 25 °C, Vbb = 12 V unless otherwise specified
Symbol
PROFET® ITS621L1
Values
Unit
min typ max
Operating Parameters
Operating voltage5)
Tj =-40...+150°C: Vbb(on)
5.0
-- 34 V
Undervoltage shutdown
Tj =-40...+150°C: Vbb(under)
3.5
-- 5.0 V
Undervoltage restart
Tj =-40...+25°C: Vbb(u rst)
Tj =+150°C:
--
-- 5.0 V
7.0
Undervoltage restart of charge pump
Vbb(ucp)
see diagram page 13
Tj =-40...+150°C:
-- 5.6 7.0 V
Undervoltage hysteresis
Vbb(under) = Vbb(u rst) - Vbb(under)
Vbb(under)
-- 0.2
-- V
Overvoltage shutdown
Tj =-40...+150°C: Vbb(over)
34
-- 43 V
Overvoltage restart
Tj =-40...+150°C: Vbb(o rst)
33
--
-- V
Overvoltage hysteresis
Tj =-40...+150°C: Vbb(over)
-- 0.5
-- V
Overvoltage protection6)
Tj =-40...+150°C: Vbb(AZ)
42 47
-- V
Ibb=40 mA
Standby current (pin 4)
VIN=0
Tj=-40...+25°C: Ibb(off)
Tj= 150°C:
-- 14 30 µA
-- 17 35
Leakage output current (included in Ibb(off))
IL(off)
--
-- 12 µA
VIN=0
Operating current (Pin 2)7), VIN=5 V
both channels on, Tj =-40...+150°C
Operating current (Pin 2)7)
one channel on, Tj =-40...+150°C:
IGND
IGND
--
4
6 mA
--
2
3 mA
5) At supply voltage increase up to Vbb= 5.6 V typ without charge pump, VOUT Vbb - 2 V
6) See also VON(CL) in table of protection functions and circuit diagram page 8.
7) Add IST, if IST > 0, add IIN, if VIN>5.5 V