HWD DC/DC Series Data Sheet
Table 1. Absolute Maximum Ratings
Parameter
Symbol
Min
Input Voltage
Continuous
Transient (100 msec)
Vi
-
Vi
-
Operating Baseplate Temperature
Tb
-40
Note 1
Storage Temperature
Tstg
-55
Input to Output Isolation
-
-
Output Short Circuit Duration
-
-
Total Output Power
No Load Power Dissipation
Pomax
-
-
Max
60
100
+100
+125
1500
Continuous
75
6
Units
VDC
VDC
°C
°C
VDC
-
W
W
Electrical Specifications
Unless otherwise indicated, specifications apply over all input voltages, resistive load, and Tbp=+40°C.
Table 2. Input Specifications
Parameter
Symbol
Min
Typ
Max
Units
Voltage Range
Vi
18*
24/48
60
VDC
Maximum Input Current
Ii
-
-
5.5
A
Input Ripple Rejection (120 Hz)
Inrush Transient
-
60
-
dB
-
-
1
A2s
Input Reflected Ripple (see figure 1)
-
-
250
mA p-p
• Module will operate within specification with an input voltage of 18 VDC, but must be turned on with an input voltage > 19.5 VDC.
See Undervoltage Lockout Specification.
Fusing Considerations
CAUTION
This DC-DC converter is not internally fused. An external input fuse must always be used.
REV. JUN 27, 2003