Electrical Characteristics (for VDD = 5V, VPP = 300V, TA = 250C)
DC Characteristics
Symbol
Parameter
Min Typ Max Units
IDD
VDD supply current
15 mA
IDDQ
Quiescent VDD supply current
IPP
High voltage supply current
200
µA
0.50 mA
0.50 mA
IIH
High-level logic input current
IIL
Low-level logic input current
VOH
High-level output
HVOUT
265
Data out VDD -1V
VOL
Low-level output
HVOUT
Data out
10
µA
-10
µA
V
V
35
V
1.0
V
VOC
HVOUT clamp voltage
VPP +1.5 V
-30
V
HV507
Conditions
fCLK = 8MHz, fDATA = 4MHz
LE = LOW
All VIN = 0V or VDD
VPP = 300V All outputs high
VPP = 300V All outputs low
VIH = VDD
VIL = 0V
VPP = 300V, IHVOUT = -1mA
IDOUT = -100µA
VDD = 5V, IHVOUT = 1mA
IDOUT = 100µA
IOC = 1mA
IOC = -1mA
AC Characteristics1 (For VDD = 5V, VPP = 300V, TA = 25°C)
Symbol
Parameter
Min Typ
fCLK
Clock frequency
tW
Clock width high and low
62
tSU
Data setup time before clock rises
35
tH
Data hold time after clock rises
30
tWLE
Width of latch enable pulse
80
tDLE
LE delay time after rising edge of clock
35
tSLE
LE setup time before rising edge of clock
40
tON, tOFF
Time from latch enable to HVOUT
tDHL
Delay time clock to data out high to low
tDLH
Delay time clock to data out low to high
tr, tf
All logic inputs
Note:
1. Shift register speed can be as low as DC as long as Data Set-up and Hold Time meet the spec.
Max Units
8 MHz
ns
ns
ns
ns
ns
ns
4
µs
125 ns
125 ns
5
ns
Conditions
CL = 20pF
CL = 20pF
CL = 20pF
Recommended Operating Conditions
Symbol
Parameter
Min
Typ
Max
VDD
Logic supply voltage
VPP
High voltage supply
VIH
High-level input voltage
VIL
Low-level input voltage
TA
Operating free-air temperature
Notes:
Power-up sequence should be the following:
1. Connect ground.
2. Apply VDD.
3. Set all inputs (Data, CLK, Enable, etc.) to a known state.
4.5
5.0
5.5
60
300
VDD -0.9
VDD
0
0.9
0
+70
4. Apply VPP.
5. The VPP should not drop below VDD or float during operation.
Power-down sequence should be the reverse of the above.
2
Units
V
V
V
V
°C