IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
(HCPL-26xx; 46xx; 6N13x Option 060 Only)
Description
Symbol
Characteristic
Units
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 300 V rms
I-IV
for rated mains voltage ≤ 450 V rms
I-III
Climatic Classification
55/85/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V x 1.875 = V , 100% Production Test with t = 1 sec,
IORM
PR
m
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V x 1.5 = V , Type and sample test,
IORM
PR
t = 60 sec, Partial Discharge < 5 pC
m
Highest Allowable Overvoltage*
(Transient Overvoltage, t = 10 sec)
ini
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 16, Thermal Derating curve.)
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
V
IORM
V
PR
V
PR
V
IOTM
T
S
I
S,INPUT
P
S,OUTPUT
RS
630
1181
945
6000
175
230
600
≥109
V
peak
V
peak
V
peak
V
peak
°C
mA
mW
:
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in applica-
tion.
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (HCNW137/2601/2611 Only)
Description
Symbol
Characteristic
Units
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤600 V rms
I-IV
for rated mains voltage ≤1000 V rms
I-III
Climatic Classification (DIN IEC 68 part 1)
55/100/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V x 1.875 = V , 100% Production Test with t = 1 sec,
IORM
PR
m
Partial Discharge < 5 pC
V
IORM
V
PR
1414
2651
V
peak
V
peak
Input to Output Test Voltage, Method a*
V x 1.5 = V , Type and sample test,
IORM
PR
t = 60 sec, Partial Discharge < 5 pC
m
Highest Allowable Overvoltage*
(Transient Overvoltage, t = 10 sec)
ini
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 16, Thermal Derating curve.)
Case Temperature
Input Current
Output Power
Insulation Resistance at T , V = 500 V
S IO
V
PR
V
IOTM
T
S
I
S,INPUT
PS,OUTPUT
R
S
2121
8000
150
400
700
≥109
V
peak
V
peak
°C
mA
mW
:
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in applica-
tion.