HA13166H
Electrical Characteristics
(unless otherwise noted, Vcc = 13.2 V, Ta = 25°C)
Item
Symbol Min Typ Max Unit
Test Condition
Standby current
IST
—
400
600
µA ACC = 0 V, CTRL = 0 V
CTRL L level (STBY mode)
VCL
0
—
1.0
V
CTRL M level (CD OFF mode)
VCM
2.0
—
3.0
V
CTRL H level (CD ON mode)
VCH
4.0
—
–
V
ANT CTRL L level (ANT OFF mode) VACL
0
—
2.0
V
ANT CTRL H level (ANT ON mode) VACH
3.0
—
–
V
VDD Output voltage
Vo1
5.4 5.7
6.0
V Io1 = 80 mA
OUT Voltage regulation
∆Vo11
—
10
50
mV Vcc = 10 to 16 V, Io1 = 80 mA
Load regulation
∆Vo12
—
50
100 mV Io1 = 0 to 80 mA
Minimum I/O voltage
differential
∆Vo13
—
1.0
1.5
V Io1 = 80 mA
Output current capacity
Io1
100 250
—
mA Vo1 ≥ 5.4 V
Ripple rejection ratio
SVR1
50
60
—
dB f = 100 Hz, Io1 = 80 mA
CD
OUT
Output voltage
Voltage regulation
Vo2
7.6 8.0
8.4
V Io2 = 1.0 A
∆Vo21
—
40
100 mV Vcc = 10 to 16V, Io2 = 1.0 A
Load regulation
∆Vo22
—
70
150 mV Io2 = 10m to 1.0 A
Minimum I/O voltage
∆Vo23
—
1.0
1.5
V Io2 = 1.0 A
differential
Output current capacity
Io2
1.3 2.0
—
A Vo2 ≥ 7.6 V
Ripple rejection ratio
SVR2
45
50
—
dB f = 100 Hz, Io2 = 1.0 A
AUDIO Output voltage
Vo3
8.5 9.0
9.5
V Io3 = 400 mA
OUT Voltage regulation
∆Vo31
—
30
90
mV Vcc = 10 to 16 V, Io3 = 400 mA
Load regulation
∆Vo32
— 100 200 mV Io3 = 10 to 400 mA
Minimum I/O voltage
∆Vo33
—
0.4
0.9
V Io3 = 400 mA
differential
Output current capacity
Io3
500 850
—
mA Vo3 ≥ 8.5 V
Ripple rejection ratio
SVR3
40
50
—
dB f = 100 Hz, Io3 = 400 mA
ILM
Output voltage
Vo4
9.5 10.0 10.5
V Io4 = 400 mA
OUT Voltage regulation
∆Vo41
—
40
100 mV Vcc = 12.5 to 16 V, Io4 = 400 mA
Load regulation
∆Vo42
—
50
100 mV Io4 = 10 to 400 mA
Minimum I/O voltage
differential
∆Vo43
—
1.0
1.5
V Io4 = 400 mA
Output current capacity
Io4
500 900
—
mA Vo4 ≥ 9.5 V
Ripple rejection ratio
SVR4
32
40
—
dB f = 100 Hz, Io4 = 400 mA
DSP
OUT
Output voltage
Voltage regulation
Vo5
∆Vo51
3.1 3.3
—
10
3.5
V Io5 = 120 mA
50
mV Vcc = 10 to 16 V, Io5 = 120 mA
Load regulation
∆Vo52
—
50
100 mV Io5 = 0 to 120 mA
Output current capacity
Io5
150 300
—
mA Vo5 ≥ 3.1 V
Ripple rejection ratio
SVR5
50
60
—
dB f = 100 Hz, Io5 = 120 mA
EXT Differential I/O voltage
∆Vo61
—
1.0
1.5
V Io6 = 300 mA
OUT Load regulation
∆Vo62
— 350 600 mV Io6 = 10 to 300 mA
Output current capacity
Io6
300 500
—
mA Vo6 ≥ 11.7 V
ANT
OUT
Differential I/O voltage
Load regulation
∆Vo71
∆Vo72
—
1.0
1.5
V Io7 = 300 mA
— 350 600 mV Io7 = 10 to 300 mA
Output current capacity
Io7
300 500
—
mA Vo7 ≥ 11.7 V
Rev.1.00 Jan 16, 2007 page 7 of 18