GA200TD120U
200 RG1=1=5OΩh;mRG2 = 0 Ω
T J = 150° C
VCC = 720V
160 VGE = 15V
120
80
40
0
0
100
200
300
400
I C , Collector Current (A)
Fig. 11 - Typical Switching Losses vs.
Collector-to-Emitter Current
1000
TJ = 125°C
100
TJ = 25°C
10
1.0
2.0
3.0
4.0
5.0
Forward V oltage D rop - V FM (V )
Fig. 13 - Typical Forward Voltage Drop vs.
Instantaneous Forward Current
6
500
VGE = 20V
T J = 125°C
V CE measured at terminal (Peak Voltage)
400
300
SAFE OPERATING AREA
200
100
0
A
0
200 400 600 800 1000 1200 1400
VCE , Collector-to-Em itter Voltage (V)
Fig. 12 - Reverse Bias SOA
20000
16000
IF = 400A
IF = 200A
IF = 100A
12000
8000
4000
VR = 720V
TJ = 1 25 °C
TJ = 25°C
0
500
1000
1500
2000
di f /dt - (A/µs)
Fig. 14 - Typical Stored Charge vs. dif/dt
www.irf.com