DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

FT2232H Ver la hoja de datos (PDF) - Future Technology

Número de pieza
componentes Descripción
Fabricante
FT2232H Datasheet PDF : 67 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Document No.: FT_000061
FT2232H DUAL HIGH SPEED USB TO MULTIPURPOSE UART/FIFO IC
Version 2.21
Clearance No.: FTDI#77
Pin No.
Name
Type
Description
2
OSCI
INPUT Oscillator input.
3
OSCO
OUTPUT Oscillator output.
6
REF
INPUT Current reference – connect via a 12KΩ resistor @ 1% to GND.
7
DM
INPUT USB Data Signal Minus.
8
INPUT USB Data Signal Plus.
DP
13
TEST
INPUT IC test pin for normal operation should be connected to GND.
14
RESET#
INPUT
60
PWREN#
OUTPUT
36
SUSPEND# OUTPUT
59
PWRSAV#
INPUT
Table 3.2 Common Function pins
Reset input (active low).
Active low power-enable output.
PWREN# = 0: Normal operation.
PWREN# =1 : USB SUSPEND mode or device has not been configured.
This can be used by external circuitry to power down logic when device
is in USB suspend or has not been configured.
Active low when USB is in suspend mode.
USB Power Save input. This is an EEPROM configurable option used
when the FT2232H is used in a self powered mode and is used to
prevent forcing current down the USB lines when the host or hub is
powered off.
PWRSAV# = 1 : Normal Operation
PWRSAV# = 0 : FT2232H forced into SUSPEND mode.
PWRSAV# can be connected to GND (via a 10KΩ resistor) and another
resistor (e.g. 4K7) connected to the VBUS of the USB connector. When
this input goes high, then it indicates to the FT2232H that it is
connected to a host PC. When the host or hub is powered down then
the FT2232H is held in SUSPEND mode.
Pin No. Name
Type
Description
63
EECS
I/O
EEPROM Chip Select. Tri-State during device reset.
EECLK
OUTPUT Clock signal to EEPROM. Tri-State during device reset. When not in reset, this
62
outputs the EEPROM clock.
EEDATA
I/O
EEPROM Data I/O Connect directly to Data-In of the EEPROM and to Data-Out
61
of the EEPROM via a 2.2K resistor. Also, pull Data-Out of the EEPROM to VCC via
a 10K resistor for correct operation. Tri-State during device reset.
Table 3.3 EEPROM Interface Group
Copyright © 2012 Future Technology Devices International Limited
11

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]