Guaranteed Electrical Characteristics, FAN4040-2.5, Industrial Temperature Range
(TA = 25°C unless otherwise specified, in free air)
The • denotes specifications which apply over the full operating temperature range.
Symbol Parameter
VR
TCVR
Reverse Breakdown Voltage
Reverse Breakdown Voltage
Tolerance
IRMIN
∆VR/∆T
Minimum Operating Current
Reverse Breakdown Voltage
Temperature Coefficient
∆VR (∆IK) Reverse Breakdown Voltage
Change with Operating Current
ZKA
eN
∆VR
*Typical.
Reverse Dynamic Impedance
Wideband Noise
Reverse Breakdown Voltage
Long-term Stability
Conditions
IK = 100µA
IK = 100µA
IK = 1mA
IRMIN ≤ IK ≤1mA
1mA ≤ IK ≤ 15mA
1mA ≤ IK ≤ 25mA
IK=1mA, f=120Hz,
IAC=0.1IK
IK=100µA,
10Hz ≤ f ≤ 10kHz
t=1000hrs, T=25°C,
IK=100µA
Limits
Units
A
B
C
D
2.500 2.500 2.500 2.500 V*
±2.5 ±5.0 ±12 ±25 mV
• ±19 ±21 ±29 ±49 mV
• 65 65 65 70
µA
• ±100 ±100 ±100 ±150 ppm/°C
• 1.2 1.2 1.2 1.5 mV
• 8.0 8.0 8.0 10.0 mV
10 10 10 12 mV*
1.0 1.0 1.0 1.3
Ω*
35 35 35 35 µVRMS*
120 120 120 120 ppm*
Guaranteed Electrical Characteristics, FAN4040-3.3, Industrial Temperature Range
(TA = 25°C unless otherwise specified, in free air)
The • denotes specifications which apply over the full operating temperature range.
Symbol Parameter
VR
TCVR
Reverse Breakdown Voltage
Reverse Breakdown Voltage
Tolerance
IRMIN
∆VR/∆T
Minimum Operating Current
Reverse Breakdown Voltage
Temperature Coefficient
∆VR (∆IK) Reverse Breakdown Voltage
Change with Operating Current
ZKA
eN
∆VR
Reverse Dynamic Impedance
Wideband Noise
Reverse Breakdown Voltage
Long-term Stability
Conditions
IK = 100µA
IK = 100µA
IK = 1mA
IRMIN ≤ IK ≤1mA
1mA ≤ IK ≤ 15mA
1mA ≤ IK ≤ 25mA
IK=1mA, f=120Hz,
IAC=0.1IK
IK=100µA,
10Hz ≤ f ≤ 10kHz
t=1000hrs, T=25°C,
IK=100µA
Limits
Units
A
B
C
D
3.300 3.300 3.300 3.300 V*
±3.3 ±6.6 ±17 ±33 mV
• ±25 ±28 ±38 ±65 mV
• 70 70 70 75
µA
• ±100 ±100 ±100 ±150 ppm/°C
• 1.2 1.2 1.2 1.5 mV
• 10 10 10 13
mV
12 12 12 15 mV*
1.0 1.0 1.0 1.3
Ω*
70 70 70 70 µVRMS*
120 120 120 120 ppm*
*Typical.
REV. 1.0.5 1/29/03