DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

B72214T2301K101 Ver la hoja de datos (PDF) - EPCOS AG

Número de pieza
componentes Descripción
Fabricante
B72214T2301K101
Epcos
EPCOS AG Epcos
B72214T2301K101 Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
Housed varistors
ThermoFuse varistors, ETFV14 series
Reliability data
Test
Varistor voltage
Clamping voltage
Surge current derating,
8/20 µs
Surge current derating,
2 ms
Abnormal overvoltage test
Test methods/conditions
Requirement
The voltage between two terminals with To meet the specified value.
the specified measuring current applied
is called Vv (1 mADC @ 0.2 … 2 s).
The maximum voltage between two
terminals with the specified standard
impulse current (8/20 µs) applied.
To meet the specified value.
CECC 42 000, test C 2.1
|V/V (1 mA)| 10%
100 surge currents (8/20 µs), unipolar,
interval 30 s, amplitude corresponding
to derating curve for 100 impulses
at 20 µs
CECC 42 000, test C 2.1
(measured in direction
of surge current)
No visible damage
|V/V (1 mA)| 10%
100 surge currents (2 ms), unipolar, (measured in direction
interval 120 s, amplitude corresponding of surge current)
to derating curve for 100 impulses
at 2 ms
No visible damage
UL1449, limited current abnormal over- Any of these phenomena
voltage test. Apply a high AC voltage shall not be observed, or
to ThermoFuse varistor, the amplitude this specimen will be
of overvoltage and current limit will be judged as failed part.
adopted from UL1449 general instruc- 1. Emission of flame,
tion in section 37. The specimen will be molten metal, glowing
tested on a softwood surface covered
or flaming particles
with a double layer of white tissue
through any openings
paper. The specimen is to be loosely
(pre-existed or created
draped with a double layer of cheese- as a result of the test)
cloth. The cheesecloth shall cover
in the product.
openings where flame, molten or other
particles may be expelled as a result of
the test. The test result will be visually
inspected.
2. Charring, glowing, or
flaming of the supporting
surface, tissue paper,
or cheesecloth.
3. Ignition of the enclosure.
4. Creation of any openings
in the enclosure that
result in accessibility of
live parts, when judged
in accordance with
accessibility of live parts,
UL1449 section 13.
Please read Cautions and warnings and
Important notes at the end of this document.
5 11/07