2.4.Lighting Specifications
2.4.1.Absolute Maximum Ratings
Parameter
Symbol
Conditions
Foward Current
IF
Note 1
Reverse Voltage
VR
-
LED Power Dissipation
PD
-
Note 1 : Refer to the foward current derating curve.
IF (mA)
750
Ta=25℃
Min. Typ. Max. Units
-
-
750
mA
-
-
6
V
-
-
4
W
321
-20
25
50 Ta (℃)
2.4.2.Operating Characteristics
Parameter
Symbol
Foward Voltage
VF
Luminance of
L
Backlight Surface
*1 : Take measurement at LED unit only.
Conditions
IF=300mA
IF=300mA*1
Ta=25℃
Min. Typ. Max. Units
3.4
4.0
5.6
V
-
50
-
cd/㎡
DMC20203NYJU-SLY-D-2 (AJ) No.99-0276
OPTREX CORPORATION
OPTREX
Page 5/16