25-40W, TRIPLE OUTPUT DC/DC CONVERTERS
TMP Models
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage and "full-load" conditions, unless noted.
INPUT
Input Voltage Range:
Q12 Models
D24 Models
Q48 Models
D48 Models
Input Current
10-36 Volts (24V nominal)
18-36 Volts (24V nominal)
18-75 Volts (48V nominal)
36-75 Volts (48V nominal)
See Ordering Guide
Input FilterType
Pi
Overvoltage Shutdown:
Q12 and D24 Models
Q48 and D48 Models
40 Volts
80 Volts
Reverse-Polarity Protection
Yes (Instantaneous, 6A maximum)
On/Off Control (Pin 5)
TTL high (or open) = on, low = off
Output
VOUT Accuracy (50% load):
+5V Output
±1%
±12V or ±15V Outputs
±3%
Temperature Coefficient
±0.02% per °C
Ripple/Noise (20MHz BW)
See Ordering Guide
Line/Load Regulation
See Ordering Guide
Efficiency
See Ordering Guide
Isolation Voltage
1500Vdc, minimum
Isolation Capacitance
500pF
Current Limiting
Continuous, auto-recovery
Overvoltage Protection
Zener/transorb clamps, magnetic fdbk.
Dynamic Characteristics
Transient Response (50% load step) 300µsec max. to ±3% of final value
Switching Frequency
125kHz (±10%)
Environmental
Operating Temperature (ambient):
Without Derating
With Derating
Maximum Case Temperature
–40 to +70°C (Model dependent)
to +95°C
+95°C
Storage Temperature
–40 to +105°C
Physical
Dimensions
2.04" x 3.04" x 0.55" (51.8 x 77.2 x 14mm)
Shielding
5-sided
Case Connection
Pin 4
Case Material
Aluminum, black anodized finish
with plastic header
Pin Material
Brass, solder coated
Weight
6 ounces (170 grams)
These converters require a minimum 10% loading on their primary output and 20% loading
on each auxiliary output to maintain specified regulation. Operation under no-load conditions
will not damage these devices; however they may not meet all listed specifications.
"Full load" varies by part number and is determined by the input voltage range as indicated by
the part number suffix. See Technical Notes and Output Power Considerations.
Applying a voltage to the On/Off Control pin when no input power is applied to the converter
can cause permanent damage to the converter. If desired, the On/Off Control function can be
replaced with a Sync function. See page 6 of this data sheet for more details.
Listed specification is for input-to-output isolation. Input-to-case and output-to-case
isolation is 1000Vdc, minimum.
Absolute Maximum Ratings
Input Voltage:
Q12/D24 Models
Q48/D48 Models
Input Reverse-Polarity Protection
Output Overvoltage Protection
+5V Output
±12V Outputs
±15V Outputs
Output Current
Storage Temperature
Lead Temperature (soldering, 10 sec.)
44 Volts
88 Volts
Current must be <6A. Brief
duration only. Fusing recommended.
6.8 Volts, limited duration
15 Volts, limited duration
18 Volts, limited duration
Current limited. Max. current and
short-circuit duration are model
dependent.
–40 to +105°C
+300°C
These are stress ratings. Exposure of devices to any of these conditions may adversely
affect long-term reliability. Proper operation under conditions other than those listed in the
Performance/Functional Specifications Table is not implied.
TECHNICAL NOTES
Filtering and Noise Reduction
All TMP 25-40 Watt DC/DC Converters achieve their rated ripple and noise
specifications without the use of external input/output capacitors. In critical
applications, input/output ripple and noise may be further reduced by
installing electrolytic capacitors across the input terminals and/or low-ESR
tantalum or electrolytic capacitors across the output terminals. Output
capacitors should be connected between their respective output pin (pin 6, 7
or 9) and Common (pin 8). The caps should be located as close to the
power converters as possible. See Figure 7. Typical values are listed in the
tables below. In many applications, using values greater than those listed will
yield better results.
To Reduce Input Ripple
Q12, D24 Models
Q48, D48 Models
47µF, 50V
10µF, 100V
To Reduce Output Ripple
+5V Output
±12/15V Outputs
47µF, 10V, Low ESR
22µF, 20V, Low ESR
In critical, space-sensitive applications, DATEL may be able to tailor the
internal input/output filtering of these units to meet your specific require-
ments. Contact our Applications Engineering Group for additional details.
Input Fusing
Certain applications and/or safety agencies may require the installation of
fuses at the inputs of power conversion components. For DATEL TMP DC/DC
Converters, you should use slow-blow type fuses with values no greater than
the following:
VIN Range
Q12
D24
Q48
D48
Fuse Value
4A
4A
3A
2A
3