CP2103
Table 3. UART and Suspend I/O DC Electrical Characteristics
VIO = VDD = 3.0 to 3.6 V, –40 to +85 °C unless otherwise specified.
Parameters
Output High Voltage (VOH)
Output Low Voltage (VOL)
Input High Voltage (VIH)
Input Low Voltage (VIL)
Input Leakage Current
Maximum Input Voltage
Conditions
IOH = –10 µA
IOH = –3 mA
IOH = –10 mA
IOL = 8.5 mA
IOL = 10 µA
weak pull-ups enabled
weak pull-ups disabled
Open drain, logic high (1)
Min
VIO – 0.1
VIO – 0.7
—
—
—
2.0
—
—
—
—
Typ
—
—
VIO – 0.8
—
—
—
—
25
—
—
Max
—
—
—
0.6
0.1
—
0.8
50
±1
5.8
UNITS
V
V
V
V
µA
V
Table 4. UART and Suspend I/O DC Electrical Characteristics (Low-Voltage Operation)
VIO = 1.8 V to 3.0 V, –40 to +85 °C unless otherwise specified.
Parameters
Output High Voltage (VOH)
Output Low Voltage (VOL)
Input High Voltage (VIH)
Input Low Voltage (VIL)
Input Leakage Current
Maximum Input Voltage
Conditions
IOH = TBD
IOH = TBD
IOH = TBD
IOL = TBD
IOL = TBD
TBD
Open drain, logic high (1)
Min
TBD
TBD
—
—
—
TBD
—
—
—
Typ
—
—
TBD
—
—
—
—
TBD
—
Max
—
—
—
TBD
TBD
—
TBD
TBD
TBD
UNITS
V
V
V
V
µA
V
Table 5. Reset Electrical Characteristics
–40 to +85 °C unless otherwise specified.
Parameter
Conditions
RST Input High Voltage
RST Input Low Voltage
Minimum RST Low Time to Gen-
erate a System Reset
Min
Typ
0.7 x VIO —
Max Units
—
V
—
— 0.3 x VIO V
15
—
—
µs
6
Preliminary Rev. 0.3