DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

V54C365324V-6 Ver la hoja de datos (PDF) - Mosel Vitelic Corporation

Número de pieza
componentes Descripción
Fabricante
V54C365324V-6 Datasheet PDF : 21 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MOSEL VITELIC
V54C365324V
Operating Currents (TA = 0 to 70°C, VCC = 3.3V ± 0.3V)
(Recommended Operating Conditions unless otherwise noted)
Symbol Parameter & Test Condition
ICC1
Operating Current
tRC = tRCMIN., tRC = tCKMIN.
Active-precharge command cycling,
without Burst Operation
1 bank operation
ICC2P Precharge Standby Current
in Power Down Mode
tCK = min.
ICC2PS
ICC2N
CS =VIH, CKEVIL(max)
Precharge Standby Current
in Non-Power Down Mode
tCK = Infinity
tCK = min.
ICC2NS CS =VIH, CKEVIL(max)
tCK = Infinity
Max.
-5 -55 -6 -7 -8 Unit Note
250 240 230 210 190 mA 3
2
2
2
2
2 mA 3
2
2
2
2
2 mA 3
35 35 35 35 35 mA
15 15 15 15 15 mA
ICC3P Active Standby Current in
Power-down mode
ICC3PS
ICC3N Active Standby Current in
non Power-down mode
ICC3NS
ICC4
Burst Operating Current
tCK = min
Read/Write command cycling
CKE ð VIL(max), tck = min
3
3
3
3
3 mA
CKE ð VIL(max), tck = infinity 3
3
3
3
3 mA
CKE Š VIL(max), tck = min
60 60 60 60 60 mA
CKE Š VIL(max), tck = infinity 50 50 50 50 50 mA
CL = 3
340 320 310 280 250 mA 3, 4
CL = 2
200 200 180 180 180
ICC5
Auto Refresh Current
tCK = min
Auto Refresh command cycling
200 190 180 160 150 mA 3
ICC6
Self Refresh Current
Self Refresh Mode, CKE=0.2V
L-Power
2
2
2
2
2 mA
400 400 400 400 400 µA
Notes:
3. These parameters depend on the cycle rate and these values are measured by the cycle rate under the minimum value of tCK and
tRC. Input signals are changed one time during tCK.
4. These parameters are measured with continuous data stream during read access and all DQ toggling.
V54C365324V Rev. 1.2 August 2001
9

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]