MOSEL VITELIC
V54C365324V
AC Characteristics (1,2,3)
TA = 0 to 70°C; VSS = 0 V; VCC = 3.3 V ± 0.3 V, tT = 1 ns
Limit Values
-5
-55
-6
-7
-8
# Symbol Parameter
Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Unit
Clock and Clock Enable
1 tCK
Clock Cycle Time
CAS Latency = 3
CAS Latency = 2
5 – 5.5 – 6 – 7 – 8 – ns
10 – 10 – 10 – 10 – 10 – ns
2 tCK
Clock Frequency
CAS Latency = 3
CAS Latency = 2
– 200 – 200 – 166 – 143 – 125 MHz
– 100 – 100 – 100 – 100 – 100 MHz
3 tAC
Access Time from Clock
CAS Latency = 3
CAS Latency = 2
‘
– 5 – 5.5
6 – 6 – 6 ns 2
–7–7
7 – 7 – 7 ns 3
4 tCH
Clock High Pulse Width
5 tCL
Clock Low Pulse Width
6 tT
Transition time
Setup and Hold Times
2.5 – 2.5 – 2.5 – 2.5 – 3 – ns
2.5 – 2.5 – 2.5 – 2.5 – 3 – ns
1 10 1 10 1 10 1 10 1 10 ns
7 tCS
Command Setup Time
8 tAS
Address Setup Time
9 tDS
Data In Setup Time
10 tCKS
CKE Setup Time
11 tCH
Command Hold Time
12 tAH
Address Hold Time
13 tDH
Data In Hold Time
14 tCKH
CKE Hold Time
Common Parameters
2 – 2 – 2 – 2 – 2.5 – ns 4
2 – 2 – 2 – 2 – 2.5 – ns 4
2 – 2 – 2 – 2 – 2.5 – ns 4
2 – 2 – 2 – 2 – 2.5 – ns 4
1 – 1 – 1 – 1 – 1 – ns 4
1 – 1 – 1 – 1 – 1 – ns 4
1.5 – 1.5 – 1.5 – 1.5 – 1.5 – ns 4
1 – 1 – 1 – 1 – 1 – ns 4
15 tRCD
16 tRAS
17 tRC
18 tRP
19 tRRD
Row to Column Delay Time
Row Active Time
Row Cycle Time
Row Precharge Time
Activate(a) to Activate(b) Command
period
15 – 16 – 16 – 16 – 16 – ns 5
40 100K 45 100K 48 100K 48 100K 48 100K ns 5
60 – 63 – 66 – 70 – 72 – ns 5
15 – 17 – 18 – 21 – 24 – ns 5
10 – 11 – 12 – 14 – 16 – ns 5
20 tCCD
CAS(a) to CAS(b) Command period 1 – 1 – 1 – 1 – 1 – CLK
21 tRCS
Mode Register Set-up time
10 – 11 – 12 – 14 – 16 – ns
22 tSB
Power Down Mode Entry Time
0 5 0 5.5 0 6 0 7 0 8 ns
Refresh Cycle
23 tREF
24 tSREX
Refresh Period (2048 cycles)
Self Refresh Exit Time
– 32 – 32 – 32 – 32 – 32 ms
2 CLK + tRC
6
V54C365324V Rev. 1.2 August 2001
10