Data Sheet AS8168
The default pulse rate of CAL is MON/MOP x 16. The default pulse rate is the pulse rate available at the output, without any
programming required to the AS8168.
(Note: As the default pulse rate of MON/MOP is 400 imp/kWh, the actual CAL default pulse rate is 400 x 16 =
6,400 imp/kWh)
As an example, the maximum selectable pulse rate of CAL is 64 * 800 = 51,200 imp/kWh (See MON/MOP below)
The CAL pulse width is fixed at 1ms and is shown in the Timing Diagram and Timing Parameters that follow.
Stepper Motor Drive Outputs (MON & MOP): The MON and MOP outputs may be used to directly drive an electromechanical
counter or a stepper motor counter. The output frequencies are proportional to the real power measured. The required format
of the signal for driving a mechanical counter, activated by a 2-phase stepper motor is provided by the difference between
the MON and MOP outputs.
The output pulse rate is programmable via the on-chip memory, with 4 pulse rate options being available:
Parameter: F_mon_sel
Setting MON/MOP Output Pulse Rate
00
100 imp/kWh
01
200 imp/kWh
10
400 imp/kWh
11
800 imp/kWh
The default MON/MOP pulse rate is set at 400 imp/kWh. The default pulse rate is the pulse rate available at the output,
without any programming required to the AS8168.
The MON and MOP outputs shown in Figure 4 are capable of driving 10mA at VOH = 4.0V and VOL = 0.4V.
The widths of the MON/MOP pulses are 200ms for all settings up to 800 imp/kWh. Above 800imp/kWh, the MON/MOP pulse
widths maintain a constant 50% duty cycle and is shown in the Timing Diagram and Timing Parameters that follows.
LED Driver Pulse Output (LED): The LED output is a low frequency output, the frequency of which is proportional to the real
power measured. The pulse rate is programmable via the on-chip memory the selected pulse rate is independent of the
settings of both the selected CAL and the MON/MOP settings.
Parameter: F_led_sel
Setting LED Output Pulse Rate
000 100 imp/kWh
001 200 imp/kWh
010 400 imp/kWh
011 800 imp/kWh
100 1600 imp/kWh
101 3200 imp/kWh
110 6400 imp/kWh
The default LED pulse rate is set at 3200 imp/kWh. The default frequency is the frequency available at the output, without
any programming required to the AS8168.
The LED output is capable of driving 10mA at VOH = 4.0V and VOL = 0.4V.
The width of the LED pulse is 80 ms for all settings except where the LED stream is shorter than 160ms. In this case, a 50%
duty cycle is maintained. The format of the LED signal is shown in the Timing Diagram and Timing Parameters below.