200
100
50
OPERATION HERE
LIMITED BY RDS (ON)
10µS
100µS
10
5
1
.5
TC =+25°C
TJ =+150°C
SINGLE PULSE
1mS
10mS
100mS
DC
.1
1
5 10
50 100
800
VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS)
FIGURE 10, MAXIMUM SAFE OPERATING AREA
20
ID = ID [Cont.]
VDS=100V
16
VDS=250V
12
VDS=400V
8
4
0
0
300 600 900 1200 1500
Qg, TOTAL GATE CHARGE (nC)
FIGURE 12, GATE CHARGES vs GATE-TO-SOURCE VOLTAGE
60,000
10,000
5,000
APT8015JVR
Ciss
Coss
1,000
Crss
500
.01
.1
1
10
50
VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS)
FIGURE 11, TYPICAL CAPACITANCE vs DRAIN-TO-SOURCE VOLTAGE
200
100
TJ =+150°C
TJ =+25°C
50
10
5
1
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
VSD, SOURCE-TO-DRAIN VOLTAGE (VOLTS)
FIGURE 13, TYPICAL SOURCE-DRAIN DIODE FORWARD VOLTAGE
r = 4.0 (.157)
(2 places)
SOT-227 (ISOTOP®) Package Outline
31.5 (1.240)
31.7 (1.248)
7.8 (.307)
8.2 (.322)
W=4.1 (.161)
W=4.3 (.169)
H=4.8 (.187)
H=4.9 (.193)
(4 places)
11.8 (.463)
12.2 (.480)
8.9 (.350)
9.6 (.378)
Hex Nut M4
(4 places)
4.0 (.157)
4.2 (.165)
(2 places)
25.2 (0.992)
0.75 (.030) 12.6 (.496) 25.4 (1.000)
0.85 (.033) 12.8 (.504)
3.3 (.129)
3.6 (.143)
1.95 (.077)
2.14 (.084)
14.9 (.587)
15.1 (.594)
* Source
Drain
30.1 (1.185)
30.3 (1.193)
38.0 (1.496)
38.2 (1.504)
* Source terminals are shorted
internally. Current handling
capability is equal for either
Source terminal.
* Source
Gate
Dimensions in Millimeters and (Inches)
ISOTOP® is a Registered Trademark of SGS Thomson.
"UL Recognized" File No. E145592
APT's devices are covered by one or more of the following U.S.patents: 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522 5,262,336
5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058