AN 209: Using Terminator Technology in Stratix & Stratix GX Devices
Figure 7. Current Draw Limitation Guidelines Using Terminator Technology
I/O Pin Sequence
of an I/O Bank
VCC
Any 10 Consecutive I/O Pins,
Excluding either RUP or RDN
or Both
GND
VCC
R UP
R DN
GND
VCC
Any 10 Consecutive I/O Pins,
Including either RUP or RDN
or Both
If the ten consecutive I/O pins exclude either RUP or RDN or both pins, the
current draw limitations in thermally enhanced BGA packages cannot
exceed 200 mA. Consult Altera Applications for current draw limit for all
other packages.
Altera Corporation
11