ASAHI KASEI
[AK5354]
FILTER CHARACTERISTICS
(Ta=25°C; VA=2.1 ∼ 3.3V, VD=1.8 ∼ 3.3; fs=44.1kHz)
Parameter
Symbol
min
typ
max
Units
ADC Digital Filter (Decimation LPF):
Passband
(Note 5) ±0.1dB
PB
0
17.4
kHz
-1.0dB
20.0
kHz
-3.0dB
21.1
kHz
Stopband
(Note 5)
SB
27.0
kHz
Passband Ripple
PR
±0.1
dB
Stopband Attenuation
SA
65
dB
Group Delay
(Note 6)
GD
17.0
1/fs
Group Delay Distortion
∆GD
0
µs
ADC Digital Filter (HPF):
Frequency Response (Note 5) -3dB
FR
3.4
Hz
-0.5dB
10
Hz
-0.1dB
22
Hz
Note:5. The passband and stopband frequencies scale with fs (sampling frequency).
For examples, PB=0.454 x fs(@ADC: -1.0dB), PB=0.454 x fs(@DAC: -0.1dB).
Note: 6. The calculating delay time which occurred by digital filtering. This time is from the input of analog signal to
setting the 20bit data of both channels to the output register for ADC and include group delay of HPF.
DC CHARACTERISTICS
(Ta=25°C; VA=2.1 ∼ 3.3V, VD=1.8 ∼ 3.3V)
Parameter
Symbol
min
Typ
High-Level Input Voltage
Low-Level Input Voltage
VIH
75%VD
-
VIL
-
-
High-Level Output Voltage (Iout=-80µA)
VOH
VD-0.4
-
Low-Level Output Voltage (Iout=80µA)
VOL
-
Input Leakage Current
Iin
-
-
max
-
25%VD
-
0.4
± 10
Units
V
V
V
V
µA
MS0054-E-01
-5-
2001/01