ADN2870
TYPICAL PERFORMANCE CHARACTERISTICS
90
60
30
0
0
20
40
60
80
100
MODULATION CURRENT (mA)
Figure 6. Rise Time vs. Modulation Current, IBIAS = 20 mA
80
60
40
20
0
0
20
40
60
80
100
MODULATION CURRENT (mA)
Figure 7. Fall Time vs. Modulation Current, IBIAS = 20 mA
45
40
35
30
25
20
15
10
5
0
20
40
60
80
100
MODULATION CURRENT (mA)
Figure 8. Deterministic Jitter vs. Modulation Current, IBIAS = 20 mA
1.2
1.0
0.8
0.6
0.4
0.2
0
0
20
40
60
80
100
MODULATION CURRENT (mA)
Figure 9. Random Jitter vs. Modulation Current, IBIAS = 20 mA
250
220
IBIAS = 80mA
190
IBIAS = 40mA
160
130
IBIAS = 20mA
100
70
40
0
20
40
60
80
100
MODULATION CURRENT (mA)
Figure 10. Total Supply Current vs. Modulation Current,
Total Supply Current = ICC + IBIAS + IMOD
60
55
50
45
40
35
30
25
20
–50 –30 –10 10
30
50
70
TEMPERATURE (°C)
90 110
Figure 11. Supply Current (ICC) vs. Temperature with ALS Asserted, IBIAS = 20 mA
Rev. A | Page 8 of 20