ADG1406/ADG1407
Parameter
POWER REQUIREMENTS
IDD
−40°C to
+25°C +85°C
0.002
ISS
0.002
VDD/VSS
1 Temperature range for B version: −40°C to +125°C.
2 Guaranteed by design, not subject to production test.
−40°C to
+125°C1
1
1
±4.5/±16.5
Unit
μA typ
μA max
μA typ
μA max
V min/max
Test Conditions/Comments
VDD = +5.5 V, VSS = −5.5 V
Digital inputs = 0 V or VDD
Digital inputs = 0 V, 5 V, or VDD
CONTINUOUS CURRENT PER CHANNEL
Table 5. ADG1406
Parameter
CONTINUOUS CURRENT PER CHANNEL1
15 V Dual Supply
28-Lead TSSOP
32-Lead LFCSP
12 V Single Supply
28-Lead TSSOP
32-Lead LFCSP
5 V Dual Supply
28-Lead TSSOP
32-Lead LFCSP
25°C
180
300
150
260
140
245
1 Guaranteed by design, not subject to production test.
85°C
100
150
90
130
85
130
125°C
50
60
50
55
45
55
Unit
mA max
mA max
mA max
mA max
mA max
mA max
Test Conditions/Comments
VDD = +13.5 V, VSS = −13.5 V
VDD = 10.8 V, VSS = 0 V
VDD = +4.5 V, VSS = −4.5 V
Table 6. ADG1407
Parameter
CONTINUOUS CURRENT PER CHANNEL1
15 V Dual Supply
28-Lead TSSOP
32-Lead LFCSP
12 V Single Supply
28-Lead TSSOP
32-Lead LFCSP
5 V Dual Supply
28-Lead TSSOP
32-Lead LFCSP
25°C
135
235
110
190
105
180
1 Guaranteed by design, not subject to production test.
85°C
85
125
70
110
65
100
125°C
45
55
40
50
40
50
Unit
mA max
mA max
mA max
mA max
mA max
mA max
Test Conditions/Comments
VDD = +13.5 V, VSS = −13.5 V
VDD = 10.8 V, VSS = 0 V
VDD = +4.5 V, VSS = −4.5 V
Rev. 0 | Page 7 of 20