PRELIMINARY TECHNICAL DATA
AD5450/AD5451/AD5452/AD5453
ABSOLUTE MAXIMUM RATINGS1, 2
(TA = +25°C unless otherwise noted)
VDD to GND
–0.3 V to +7 V
VREF, RFB to GND
–12 V to +12 V
IOUT1 to GND
–0.3 V to +7 V
Input Current to any pin except supplies
±10 mA
Logic Inputs & Output3
-0.3V to VDD +0.3 V
Operating Temperature Range
Industrial (Y Version)
–40°C to +125°C
Storage Temperature Range
–65°C to +150°C
Junction Temperature
8 lead MSOP θJA Thermal Impedance
8 lead TSOT θJA Thermal Impedance
Lead Temperature, Soldering (10seconds)
+150°C
206°C/W
211°C/W
300°C
IR Reflow, Peak Temperature (<20 seconds)
+235°C
NOTES
1Stresses above those listed under “Absolute Maximum Ratings” may cause permanent
damage to the device. This is a stress rating only and functional operation of the device
at these or any other conditions above those listed in the operational sections of this
specification is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect device reliability. Only one absolute maximum rating may
be applied at any one time.
2 Transient currents of up to 100mA will not cause SCR latchup.
3Overvoltages at SCLK, SYNC, DIN, will be clamped by internal diodes. Current
should be limited to the maximum ratings given.
Model
Resolution
AD5450YUJ 8
AD5451YUJ 10
AD5452YUJ 12
AD5452YRM 12
AD5453YUJ 14
AD5453YRM 14
INL
±0.25
±0.25
±0.5
±0.5
±2
±2
ORDERING GUIDE
Temperature Range
-40 oC to +125 oC
-40 oC to +125 oC
-40 oC to +125 oC
-40 oC to +125 oC
-40 oC to +125 oC
-40 oC to +125 oC
Package Description Branding
TSOT
TSOT
TSOT
MSOP
TSOT
MSOP
Package Option
UJ-8
UJ-8
UJ-8
RM-8
UJ-8
RM-8
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD5450/AD5451/AD5452/AD5453 features proprietary ESD protection circuitry,
permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore,
proper ESD precautions are recommended to avoid performance degradation or loss of functionality.
4