A 74-10, A 74-11
General Specifications
Pollution degree
Ambient temperature
Housing
Dimensions
Material
A74-10
A74-11
Weight
A 74-10
A 74-11
Connection cable
Approval
CE Marking
3 (IEC 60664)
- 20 to + 60°C (- 4 to + 140°F)
120 x 45 x 16 mm
150 x 114 x 23
ABS
200 g
750 g
2 m PVC, 4 x 0.4 mm2
UL
Yes
Mode of Operation
The current metering trans-
former is connected to the
current control relays H 475
as follows:
ductor through the hole sever-
al times makes it possible to
meter currents below the no-
minal range.
Red core to term. 5
White core to term. 6
Yellow core to term. 7
Black core to term. 8.
(starpoint - neutral).
- U1.
- U2.
- U3.
The metered conductor is
drawn through the central
hole of the current metering
transformer. Drawing the con-
If the conductor is drawn
through the central hole e.g. 5
times, the metering trans-
former will register 50 A when
the current in the conductor is
10 A.
In amplitude and phase the
output voltage is proportional
to the phase current metered.
Wiring Diagrams
Input current
Correct connection
Output voltage
U1 Red
Incorrect connection
U3 Yellow
Black
U2 White
U1 Red
U2 White
U3 Yellow
Black
Red
White
Yellow
Black
Dimensions
A 74-10 ..
A 74-11 ..
2
Specifications are subject to change without notice (19.07.06)