Absolute Maximum Ratings1
Free air temperature range
Symbol
Parameter
Limits
Units
VCC
DC Supply Voltage2, 3, 4 –0.5 to +7.0
V
VI
Input Voltage
–0.5 to VCC +0.5 V
VO
Output Voltage
–0.5 to VCC +0.5 V
IIO
I/O Source Sink
Current5
±20
mA
TSTG Storage Temperature
–65 to +150 °C
Notes:
1. Stresses beyond those listed under “Absolute Maximum Ratings”
may cause permanent damage to the device. Exposure to
absolute maximum rated conditions for extended periods may
affect device reliability. Devices should not be operated outside
the recommended operating conditions.
2. VPP = VCC , except during device programming.
3. VSV = VCC , except during device programming.
4. VKS = GND , except during device programming.
5. Device inputs are normally high impedance and draw extremely
low current. However, when input voltage is greater than VCC +
0.5V or less than GND – 0.5V, the internal protection diode will be
forward biased and can draw excessive current.
Recommended Operating Conditions
Parameter
Commercial Military
Units
Temperature
Range1
Power Supply
Tolerance2
0 to +70 –55 to +125 °C
±5
±10
%VCC
Notes:
1. Ambient temperature (TA) is used for commercial and
industrial; case temperature (TC) is used for military.
2. All power supplies must be in the recommended operating range.
For more information, refer to the Power-Up Design Considerations
application note at http://www.actel.com/appnotes.
Electrical Specifications
Commercial
Military
Symbol Parameter
Test Condition
Min.
Max.
Min.
Max.
VOH1, 2
VOL1, 2
VIH
VIL
IIN
IOZ
CIO
ICC(S)
HIGH Level Output
LOW Level Output
HIGH Level Input
IOH = –4 mA (CMOS)
IOH = –6 mA (CMOS)
IOL = +6 mA (CMOS)
TTL Inputs
LOW Level Input
TTL Inputs
Input Leakage
3-state Output Leakage
I/O Capacitance3, 4
VI = VCC or GND
VO = VCC or GND
Standby VCC Supply Current VI = VCC or GND, IO = 0 mA
ACT 1
3.84
2.0
–0.3
–10
–10
0.33
VCC + 0.3
0.8
+10
+10
10
3
3.7
2.0
–0.3
–10
–10
0.4
VCC + 0.3
0.8
+10
+10
10
20
ACT 2/3/1200XL/3200DX
2
20
ICC(D)
Dynamic VCC Supply Current
See the “Power Dissipation” section on page 11.
Notes:
1. Actel devices can drive and receive either CMOS or TTL signal levels. No assignment of I/Os as TTL or CMOS is required.
2. Tested one output at a time, VCC = min.
3. Not tested; for information only.
4. VOUT = 0V, f = 1 MHz
Units
V
V
V
V
V
µA
µA
pF
mA
mA