1 2 3 4 5 6 7 8 9 10 Next Last
NXP Semiconductors
74AHC3G14; 74AHCT3G14
Inverting Schmitt trigger
Table 9. Dynamic characteristics …continued
GND = 0 V; tr = tf 3.0 ns; for test circuit see Figure 7.
Symbol Parameter Conditions
25 °C
40 °C to +85 °C 40 °C to +125 °C Unit
Min Typ Max Min Max
Min
Max
74AHCT3G14
tpd
propagation nA to nY;
[1]
delay
VCC = 4.5 V to 5.5 V
[3]
CL = 15 pF
- 4.1 7.0 1.0
8.0
1.0
9.0 ns
CL = 50 pF
- 5.9 8.5 1.0
10.0
1.0
11.0 ns
CPD
power
per buffer;
[4] -
12
-
-
-
-
-
pF
dissipation CL = 50 pF; fi = 1 MHz;
capacitance VI = GND to VCC
[1] tpd is the same as tPLH and tPHL.
[2] Typical values are measured at VCC = 3.3 V.
[3] Typical values are measured at VCC = 5.0 V.
[4] CPD is used to determine the dynamic power dissipation PD (µW).
PD = CPD × VCC2 × fi + Σ (CL × VCC2 × fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in V;
Σ(CL × VCC2 × fo) = sum of the outputs.
13. Waveforms
A input
Y output
VM
tPHL
VM
The test data is given in Table 10
tPLH
mna033
Fig 6. The input (nA) to output (nY) propagation
delays
Table 10. Test data
Type number
74AHC3G14
74AHCT3G14
Input
VI
GND to VCC
GND to 3.0 V
VCC
PULSE
VI
GENERATOR
VO
DUT
RT
CL
mna101
Fig 7.
Test data is given in Table 10.
Definitions for test circuit:
CL = Load capacitance.
RT = Termination resistance should be equal to output
impedance Zo of the pulse generator.
Load circuit for measuring switching times
VM
0.5 × VCC
1.5 V
Output
VM
0.5 × VCC
0.5 × VCC
74AHC_AHCT3G14_4
Product data sheet
Rev. 04 — 5 May 2009
© NXP B.V. 2009. All rights reserved.
7 of 16