2MBI1000VXB-170E-50
IGBT Modules
http://www.fujielectric.com/products/semiconductor/
Definition of on-state voltage at terminal and switching characteristics
Main C1
Main C2E1
Sense C1
VCE (terminal)
G1 of Upper arm
Sense C2E1
Fuji defined VCE value of terminal by using
Sense C1 and Sense C2E1 for Upper arm and
Sense C2E1 and Sense E2 for Lower arm .
Switching characteristics of VCE also is defined
between Sense C1 and Sense C2E1 for Upper arm and
Sense C2E1 and Sense E2 for Lower arm .
Please use these terminals whenever
G2
VCE (terminal)
of Lower arm
measure spike voltage and on-state voltage .
Main E2
Sense E2
6