BH1750FVI
Technical Note
●Electrical Characteristics ( VCC = 3.0V, DVI = 3.0V, Ta = 25℃, unless otherwise noted )
Parameter
Symbol
Min.
Typ.
Max.
Supply Current
Icc1
-
120
190
Units Conditions
µA Ev = 100 lx ※1
Powerdown Current
Icc2
-
0.01
1.0
µA No input Light
Peak Wave Length
λp
-
560
-
nm
Measurement Accuracy
Dark ( 0 lx ) Sensor out
S/A
0.96
1.2
1.44
times
Sensor out / Actual lx
EV = 1000 lx ※1, ※2
S0
0
0
3
count H-Resolution Mode ※3
H-Resolution Mode Resolution
rHR
-
1
-
lx
L-Resolution Mode Resolution
rLR
-
4
-
lx
H-Resolution Mode Measurement
Time
tHR
-
120
180
ms
L-Resolution Mode Measurement
Time
tLR
-
16
24
ms
Incandescent / Fluorescent Sensor
out ratio
rIF
-
1
-
times EV = 1000 lx
ADDR Input ‘H’ Voltage
VAH
0.7 * VCC
-
-
V
ADDR Input ‘L’ Voltage
VAL
-
-
0.3 * VCC
V
DVI Input ‘L’ Voltage
VDVL
-
-
0.4
V
SCL, SDA Input ‘H’ Voltage 1
VIH1
0.7 * DVI
-
-
V DVI ≧ 1.8V
SCL, SDA Input ‘H’ Voltage 2
VIH2
1.26
-
-
V 1.65V ≦ DVI <1.8V
SCL, SDA Input ‘L’ Voltage 1
VIL1
-
-
0.3 * DVI
V DVI ≧ 1.8V
SCL, SDA Input ‘L’ Voltage 2
VIL2
-
-
DVI – 1.26 V 1.65V ≦ DVI < 1.8V
SCL, SDA, ADDR Input ‘H’ Current
IIH
-
-
10
µA
SCL, SDA, ADDR Input ‘L’ Current
IIL
-
-
10
µA
I2C SCL Clock Frequency
fSCL
-
-
400
kHz
I2C Bus Free Time
tBUF
1.3
-
I2C Hold Time ( repeated ) START
Condition
tHDSTA
0.6
-
I2C Set up time for a Repeated
START Condition
tSUSTA
0.6
-
-
µs
-
µs
-
µs
I2C Set up time for a Repeated STOP
Condition
tSUSTD
0.6
-
-
µs
I2C Data Hold Time
tHDDAT
0
-
0.9
µs
I2C Data Setup Time
tSUDAT
100
-
-
ns
I2C ‘L’ Period of the SCL Clock
tLOW
1.3
-
-
µs
I2C ‘H’ Period of the SCL Clock
tHIGH
0.6
-
-
µs
I2C SDA Output ‘L’ Voltage
VOL
0
-
0.4
V IOL = 3 mA
※1 White LED is used as optical source.
※2 Measurement Accuracy typical value is possible to change '1' by "Measurement result adjustment function".
※3 Use H-resolution mode or H-resolution mode2 if dark data ( less than 10 lx ) is need.
www.rohm.com
© 2009 ROHM Co., Ltd. All rights reserved.
2/17