1 2
Current Transducer LAH 25-NP
For the electronic measurement of currents : DC, AC, pulsed ...,
with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
IPN = 8-12-25 A
16038
Electrical data
IPN Primary nominal r.m.s. current
IP
Primary current, measuring range 1)
RM Measuring resistance @
25
At
0 .. 55
At
TA = 70°C TA = 85°C
R R R R M min Mmax M min Mmax
with ± 12 V
with ± 15 V
@ IPN [± At DC ]
@ IPN [At RMS ] 2)
@ IPN [± At DC ]
@ IPN [At RMS ] 2)
@ IP
<
I 3)
PN
0 257 0 252
0 155 0 150
67 371 70 366
67 236 70 231
ISN Secondary nominal r.m.s. current
25
mA
K N Conversion ratio
1 - 2 - 3 : 1000
VC Supply voltage (± 5 %)
± 12 .. 15
V
IC
Current consumption
10 (@ ± 15V) + I m A
S
Vd
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn 5
kV
Vb
R.m.s. rated voltage 4)
600
V
Accuracy - Dynamic performance data
X
εL
Accuracy 5) @ IPN, TA = 25°C
Linearity error
IO
IOM
IOT
tr a
tr
di/dt
f
Offset current @ TA = 25°C
Residual current @ IP = 0, after an overload of 5 x IPN
Thermal drift of IO
0°C .. + 70°C
- 25°C .. + 85°C
Reaction time @ 10 % of IPN
Response time 6) @ 90 % of IPN
di/dt accurately followed
Frequency bandwidth (- 1 dB)
± 0.3
%
< 0.2
%
Typ Max
± 0.15 m A
± 0.20 ± 0.25 m A
± 0.10 ± 0.60 m A
± 0.10 ± 0.70 m A
< 200
< 500
> 200
DC .. 200
ns
ns
A/µ s
kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
R S Secondary coil resistance
m Mass
- 25 .. + 85
°C
- 40 .. + 90
°C
@ TA = 70°C 99
@ TA = 85°C 104
20
g
Standards
EN 50178 : 1997
Notes : 1)During 10 s, with RM 109 (VC = ± 15 V) - 2) 50 Hz Sinusoidal -
3) The measuring resistance RM min may be lower (see "LAH Technical Informa-
tion" leaflet) - 4) Pollution class 2, cat. III - 5) Without IO & IOM - 6) With a di/dt of
100 A/µs - 7)
Features
Closed loop (compensated) multi-
range current transducer using the
Hall effect
Printed circuit board mounting
Insulated plastic case recognized
according to UL 94-V0.
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
060213/5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
page 1/2
LEM
www.lem.com

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]