DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HTA400-S(2000) Ver la hoja de datos (PDF) - LEM Industrial

Número de pieza
componentes Descripción
Fabricante
HTA400-S
(Rev.:2000)
LEM
LEM Industrial LEM
HTA400-S Datasheet PDF : 2 Pages
1 2
Current Transducer HTA 100..1000-S
For the electronic measurement of DC, AC and pulsed currents,
with a galvanic isolation between the primary (high power) circuit
and the secondary (electronic) circuit.
IPN = 100 A
Electrical data
Primary nominal
r.m.s. current
IPN (A)
100
200
300
400
500
600
1000
Primary current
measuring range
IP (A)
± 300
± 600
± 900
± 1000
± 1000
± 1000
± 1000
ÎP
Overload capacity (Ampere Turns)
VOUT Analogue output voltage @ ± IPN
RL
Load resistance TA = 0 .. + 70°C
TA = - 25 .. + 85°C
VC
Supply voltage (± 5 %)
IC
Current consumption (max)
Vb
Rms rated voltage1)
Vd
Rms voltage for AC isolation test, 50 Hz, 1 mn
Ris
Isolation resistance @ 500 VDC
Accuracy - Dynamic performance data
X
εL
Accuracy 2) @ IPN, TA = 25°C, @ ± 15 V
Linearity 2)
VOE
VOM
ε VOT
TC G
tr
di/dt
f
Electrical offset voltage @ IP = 0, TA = 25°C
Residual offset voltage @ IP = 0
after an overload of 3 x IPN
Thermal drift of offset voltage TA = - 25 .. + 85°C
Thermal drift of gain TA = - 25 .. + 85°C
Response time @ 90 % of IP
di/dt accurately followed
Frequency bandwidth (- 3 dB) 3)
Type
HTA 100-S
HTA 200-S
HTA 300-S
HTA 400-S
HTA 500-S
HTA 600-S
HTA 1000-S
30000
A
±4
V
>1
k
>3
k
± 15
V
25
mA
500
V
3
kV
> 500
M
±1
± 0.5
Max
± 10
± 10
±1
± 0.05
<3
> 50
DC .. 50
%
%
mV
mV
mV/°K
%/°K
µs
A/µs
kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
m
Mass
- 25 .. + 85
°C
- 25 .. + 85
°C
230
g
Standards Safety
EN50178 (1994)
EMC
EN50082-2 (1992)
EN50081-1 (1992)
Deviation in output when tested to EN 61000-4-6
Deviation in output when tested to EN 61000-4-4
< 10
< 10
% of IPN
% of IPN
Notes : 1) Overvoltage Category III, Pollution Degree 2
2) Excludes the electrical offset
3) Refer to derating curves in the technical file to avoid excessive core
heating at high frequency
Features
Open loop transducer using Hall
Effect
Panel mounting - Horizontal or
Vertical
Insulated plastic case to UL 94-V0.
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external
interference
Current overload capability
Low power consumption
Wide dynamic range, 100 to 1000 A
in one package.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptable Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
001107/1
LEM Components
www.lem.com

Share Link: 