DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

IEC61000-4-5 Ver la hoja de datos (PDF) - Unspecified

Número de pieza
componentes Descripción
Fabricante
IEC61000-4-5 Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
Panel Mount Power Supply 5V 35W 1Phase
PROTECTION
Over Voltage Protection
Over Load, Over Current Protection
Over Temperature Protection
Short Circuit Protection
6.5V +10%/-10%, SELV output, Hicc-up Mode, Non-Latching
(Auto recovery).
> 120% of rated load current, Hicc-up Mode, Non-Latching
(Auto recovery).
< 75°C Ambient Temp@ 100% load. Non-Latching (Auto-
recovery).
Hicc-up Mode, Non-Latching, (Auto-recovery when the fault is
removed).
Over Load Protection
The Power Supply is provided with an overload
protection (OLP/OCP) function which protects the power
supply from possible damage by over current.
Additionally power supply also has over temperature
protection (OTP) in case the over load condition persists
for a longer duration and is below the overload trigger
point but > 100% load. Typically the over load current
(IOL) is > ISURGE (120%) output voltage will start drooping
down when the power supply reaches max power limit
and will run into bouncing mode when the output reaches
UVLO (under voltage point). The output voltage will
recover automatically when the overload condition is
removed.
Over Temperature Protection
The Power Supply has an over temperature protection
(OTP). This is activated when the overload condition
persists for an extended duration and the output current
is below the overload trigger point but >100% load.
In the event of a higher ambient operating condition at
100% load, the Power Supply will run into OTP when the
ambient temperature is > 55°C. When activated, the
output voltage will go into bouncing mode until the
operating ambient temperature drops to 50°C or output
capacity is reduced as recommended in the graph.
Over Voltage Protection
The Power Supply has an overvoltage protection (OVP)
and is activated when the power supply feedback circuit
fails. The output voltage will not be > 6.5V +/-10% under
any Line/Load and operating ambient temperature.
The Power Supply does not shut down but goes into
Hiccup mode (Auto-Recovery) which is 6.5V +/- 10%.
The output voltage will recover back to 5Vdc once the
fault is removed
Short Circuit Protection
The Power Supply also has a short circuit protection
which is in line with the overload protection and
activates whenever there is a short across the output
voltage, output goes in bouncing mode and remains
until the fault is removed.
www.DeltaPSU.com