DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

BTS728L2 Ver la hoja de datos (PDF) - Siemens AG

Número de pieza
componentes Descripción
Fabricante
BTS728L2 Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
BTS 728 L2
Input circuit (ESD protection), IN1 or IN2
IN
RI
ESD-ZD I
II
GND
The use of ESD zener diodes as voltage clamp at DC
conditions is not recommended.
Status output, ST1 or ST2
+5V
R ST(ON)
ST
GND
ESD-
ZD
Overvolt. and reverse batt. protection
+ 5V
+ Vbb
R ST
VZ2
IN R I
Logic
R ST ST
VZ1
OUT
PROFET
R GND
Signal GND
GND R Load
Load GND
VZ1 = 6.1 V typ., VZ2 = 47 V typ., RGND = 150 ,
RST= 15 k, RI= 3.5 ktyp.
In case of reverse battery the load current has to be
limited by the load. Temperature protection is not active
Open-load detection OUT1 or OUT2
ON-state diagnostic
Open load, if VON < RON·IL(OL); IN high
ESD-Zener diode: 6.1 V typ., max 5.0 mA; RST(ON) < 375
at 1.6 mA. The use of ESD zener diodes as voltage clamp at
DC conditions is not recommended.
Inductive and overvoltage output clamp,
OUT1 or OUT2
+Vbb
ON
Logic
unit
Open load
detection
+ Vbb
VON
OUT
VZ
V ON
OUT
GND disconnect
Power GND
VON clamped to VON(CL) = 47 V typ.
Vbb VIN VST
IN
Vbb
PROFET OUT
ST
GND
VGND
Any kind of load. In case of IN = high is VOUT VIN - VIN(T+).
Due to VGND > 0, no VST = low signal available.
Semiconductor Group
Page 8
1999-Mar-23

Share Link: 