Data Sheet
AS3588A
Instruction 5: Connection Memory Extraction
Control Signals
Data Bus
Comments
SEL C/D CS WR RD D7 D6 D5 D4 D3 D2 D1 D0
X 0 0 0 1 X X X X X BO2 BO1 BO0 Byte 1: PCM output line
X 0 0 0 1 X X X CO4 CO3 CO2 CO1 CO0 Byte 2: PCM output channel
X 1 0 0 1 X X X X 1 0 0 0 Instruction Byte
1 0 0 1 0 C7 C6 C5 C4 C3 C2 C1 C0 OR1: LSB of CM
1 1 0 1 0 A7 A6 A5 C8 OP3 OP2 OP1 OP0 OR2: MSB of CM
(BO2) (BO1) (BO0) C8 (1) (0) (0) (0) Data is from CM
Instruction 6: Channel 0 Extraction
Control Signals
Data Bus
Comments
SEL C/D CS WR RD D7 D6 D5 D4 D3 D2 D1 D0
X 0 0 0 1 X X X X X MI7 MI6 MI5 Byte 1: MSB of selection mask
X 0 0 0 1 X X X MI4 MI3 MI2 MI1 MI0 Byte 2: LSB of selection mask
1 1 0 0 1 X X X X 1 1 1 0 Instruction Byte
Mask Store Control
1 0 0 1 0 X X X X X X X X OR1: unchanged
1 1 0 1 0 N2 N1 N0 TN 1 1 1 0 OR2: see Note 1
First Data Transfer
1 0 0 1 0 X X X X X X X X OR1: unchanged
1 1 0 1 0 N2 N1 N0 Tn 1 1 1 0 OR2: see Note 2
Repeated Data Transfer
1 0 0 1 0 D7 D6 D5 D4 D3 D2 D1 D0 OR1: expected message
1 1 0 1 0 P2 P1 P0 Fn 1 1 1 0 OR2: See Note 3
Note 1: Reading OR 2 is optional after mask store or redefinition, because the instruction is only activated by a not zero mask
Note 2: After the mask store operation (N2 N1 N0) is the sum of activated channels; after DR it is the sum of active channels;
Tn = 1 means activation of the function after mask store. After DR only Tn=1 can appear to flag a not zero mask writing.
Note 3: Reading of OR2 is mandatory after DR in order to step the data transfer; reading OR1 is also needed to scan in the
descending order of priority. Only relevant messages are considered, that means only messages with a signature different from
01. (P2 P1 P0) is the PCM bus on which the message in OR1 was found; Fn is a continuation bit which flags with a 1/0 level