DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TMA0512D Ver la hoja de datos (PDF) - TRACO Electronic AG

Número de pieza
componentes Descripción
Fabricante
TMA0512D
TRACOPOWER
TRACO Electronic AG TRACOPOWER
TMA0512D Datasheet PDF : 3 Pages
1 2 3
DC/DC Converters
TMA Series
1 Watt
Input Specifications
Input current no load /full load
5 Vin models:
12 Vin models:
15 Vin models:
24 Vin models:
30 mA / 270 mA typ.
12 mA / 110 mA typ.
11 mA / 90 mA typ.
7 mA / 55 mA typ.
Surge voltage (1 s max.)
5 Vin models:
12 Vin models:
15 Vin models:
24 Vin models:
9 V max.
18 V max.
18 V max.
30 V max.
Reverse polarity input current 0.3 A max.
Reflected input ripple current can be reduced by ext. 1–3.3 µF polyester film
capacitor
Input filter internal capacitors
Output Specifications
Voltage set accuracy ±1 % typ. / ±3 % max.
Voltage balance (dual output models, balanced loads) ±0.1 % typ. / ±1 % max.
Regulation
– Input variation (1 % change Vin) 1.2 % typ. / 1.5 % max.
– Load variation (20 – 100 %) 5 to 10 % max. (depending on model)
Ripple and noise (20 MHz Bandwidth) 50 mVp-p typ. / 75 mVp-p max.
Temperature coefficient ±0.01 %/K typ. / ±0.02 %/K max.
Short circuit protection limited 0.5 s max.
Capacitive load
Single output models: 220 µF max.
Dual output models: 100 µF max.
General Specifications
Temperature ranges
– Operating –40°C to +85°C
– Case temperature +90°C max.
– Storage –50°C to +125°C
Derating 3.3, 5 and ±5 VDC output models: 4 %/K above 75°C
all other output models: 4 %/K above 80°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >2’000’000 h
Isolation Test Voltage (Input/Output, 60s) 1‘000 VDC
Insulation System Functional
Isolation Capacitance (Input/Output) 60 pF typ. / 100 pF max.
Isolation Resistance (Input/Output) >1‘000 MOhm
Switching Frequency 70 to 120 kHz (frequency modulation)
Environmental Compliance – Reach www.tracopower.com/products/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
Supporting documents: www.tracopower.com/overview/tma
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 3

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]